Risk factors attributed to failure of ultrasound-guided compression for post-cardiac catheterization femoral artery pseudoaneurysms

6Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Femoral pseudoaneurysm is the most important access site complication following cardiac catheterization. Ultrasound-guided compression repair is a safe and effective therapeutic modality with variable failure rates and risk factors. The aim of this study was to investigate which factors were associated with a higher incidence of ultrasound-guided compression repair failure for post-cardiac catheterization femoral pseudoaneurysm. Methods: Data were retrospectively collected from medical records at King Abdullah University Hospital during the period from January 2011 to December 2016. A total of 42 patients with post-cardiac catheterization femoral pseudoaneurysm had attempted ultrasound-guided compression repair. Data regarding patients, procedure and aneurysm-related factors were evaluated by univariate analysis and multivariate logistic regression. Results: Ultrasound-guided compression repair failed in 31% of the patients. Patients with body mass index of ⩾28 kg/m2, platelet count of ⩽180,000/L, time lag (age of aneurysm) of >48 h following puncture time, aneurysmal neck diameter of ⩾4 mm and communicating tract length of <8 mm were associated with higher rate of ultrasound-guided compression repair failure in the univariate analysis. In the multivariate analysis, time lag (age of aneurysm) > 48 h (odds ratio = 5.7), body mass index ⩾ 28 kg/m2 (odds ratio = 7.8), neck diameter > 4 mm (odds ratio = 14.4) and tract length < 8 mm (odds ratio = 18.6) were significantly associated with ultrasound-guided compression repair failure. Conclusion: Ultrasound-guided compression repair for patients with post-cardiac catheterization femoral pseudoaneurysm was successful in 69% of the patients. Risk factors for failed ultrasound-guided compression repair were as follows: delayed ultrasound-guided compression repair of >48 h, body mass index ⩾ 28 kg/m2, wide neck diameter > 4 mm and short aneurysmal communication tract < 8 mm.

Cite

CITATION STYLE

APA

Shatnawi, N. J., Al-zoubi, N. A., Jarrah, J., Khader, Y., Heis, M., & Al-Omari, M. H. (2019). Risk factors attributed to failure of ultrasound-guided compression for post-cardiac catheterization femoral artery pseudoaneurysms. SAGE Open Medicine, 7. https://doi.org/10.1177/2050312119843705

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free