Diagnostic performance of 18F-DCFPyL positron emission tomography/computed tomography for biochemically recurrent prostate cancer and change-of-management analysis

6Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

Introduction: Conventional imaging (CI) performs poorly to identify sites of disease in biochemically recurrent prostate cancer. 68Ga-PSMA-11 positron emission tomography/ computed tomography (PET/CT) is most studied but has a very short half-life. This study reports the diagnostic performance of the novel prostate-specific membrane antigen (PSMA) radiotracer 18F-DCFPyL using real-life data, and tumor board simulation to estimate the impact of 18F-DCFPyL PET on patient management. Methods: Ninety-three 18F-DCFPyL PET/CT scans performed for patients previously treated for prostate cancer with a rising prostate-specific antigen (PSA) were retrospectively compared to contemporary CI, and clinical, imaging and PSA followups. A chart review was performed to document prior imaging, pathology results, serial serum PSA measurements, and other pertinent clinical data. Clinical utility of 18F-DCFPyL PET was measured using a simulated tumor board formed by three physicians with extensive prostate cancer experience deciding on management with and without knowledge of PET/CT results. Results: At median PSA 2.27 (interquartile rage [IQR] 5.27], 82% of 18F-DCFPyL PET/CT demonstrated at least one site of disease: non-regional lymph nodes (37% of scans), regional lymph node metastases (28%), local recurrence (27%), bone metastases (20%), with higher PET positivity at higher PSA. Compared to 18F-DCFPyL PET/CT, CI showed overall poor performance, with accuracy below 20% for all extent of disease. PET/CT changed management in 44% of cases. The most frequent scenario was a radical change from initiating androgen deprivation therapy (ADT) to stereotactic body radiotherapy (SBRT) of oligo-lesional disease. In univariate and multivariate analysis, no patient characteristic could predict change of management by PET/CT results. Conclusions: 18F-DCFPyL significantly outperforms CI in recurring prostate cancer and is likely to impact management.

Cite

CITATION STYLE

APA

Chaussé, G., Ben-Ezra, N., Stoopler, M., Levett, J. Y., Niazi, T., Anidjar, M., … Probst, S. (2020). Diagnostic performance of 18F-DCFPyL positron emission tomography/computed tomography for biochemically recurrent prostate cancer and change-of-management analysis. Canadian Urological Association Journal, 15(6). https://doi.org/10.5489/CUAJ.6817

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free