Modified cardiopulmonary bypass with low priming volume for blood conservation in cardiac valve replacement surgery

1Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The adverse effects of cardiopulmonary bypass during open cardiac surgery, including hemodilution, seem to be inevitable, especially for patients who generally have a relatively lower BMI with relatively small blood volumes. This study reports the modification and use of a cardiopulmonary bypass (CPB) system to reduce priming volume and hemodilution. Methods: This is a retrospective study of 462 adult patients who underwent cardiac valve replacement surgery from January 2019 to September 2021 at the General Hospital of Western Theater Command. The modified group consisted of 212 patients undergoing modified CPB. The control group included 250 patients receiving conventional CPB. Evaluated indices included fluid intake and output volumes during CPB, intraoperative indices related to CPB operation, usage of blood products during the peri-CPB period, and postoperative outcomes. Results: The modified group displayed a significant reduction in the crystalloid (200 mL vs. 600 mL, P < 0.05) and colloid priming volumes (450 mL vs. 1100 mL, P < 0.05), and ultrafiltration solution volume (750 mL vs. 1200 mL, P < 0.05). Furthermore, the modified group had a significantly lower rate of defibrillation (30.2% vs. 41.2%, P < 0.05). The intraoperative urine volume (650 mL vs. 500 mL, P < 0.05) and intraoperative hematocrit (Hct) (26% vs. 24%, P < 0.05) of the modified CPB group were also higher than in the control group. The modified group required a lower infusion volume of packed red blood cells (250 mL vs. 400 mL, P < 0.05) and lower infusion rates of packed red blood cells (17.9% vs. 25.2%, P < 0.05) and fresh frozen plasma (1.41% vs. 5.2%, P < 0.05). In addition, the modified group showed significantly improved indices related to postoperative recovery. Conclusions: The modified CPB system effectively conserves blood and shows noteworthy potential for application in cardiac valve replacement surgery.

Cite

CITATION STYLE

APA

Yang, K., Huang, H., Dai, R., Zhang, J., Wei, X., Gao, F., … Xin, M. (2023). Modified cardiopulmonary bypass with low priming volume for blood conservation in cardiac valve replacement surgery. Journal of Cardiothoracic Surgery, 18(1). https://doi.org/10.1186/s13019-023-02175-8

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free