Energy analysis of a dual-source heat pump coupled with phase change materials

14Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

Abstract

Installation costs of ground heat exchangers (GHEs) make the technology based on ground-coupled heat pumps (GCHPs) less competitive than air source heat pumps for space heating and cooling in mild climates. A smart solution is the dual source heat pump (DSHP) which switches between the air and ground to reduce frosting issues and save the system against extreme temperatures affecting air-mode. This work analyses the coupling of DSHP with a flat-panel (FP) horizontal GHE (HGHE) and a mixture of sand and phase change materials (PCMs). From numerical simulations and considering the energy demand of a real building in Northern Italy, different combinations of heat pumps (HPs) and trench backfill material were compared. The results show that PCMs always improve the performance of the systems, allowing a further reduction of the size of the geothermal facility. Annual average heat flux at FP is four times higher when coupled with the DSHP system, due to the lower exploitation. Furthermore, the enhanced dual systems are able to perform well during extreme weather conditions for which a sole air source heat pump (ASHP) system would be unable either to work or perform efficiently. Thus, the DSHP and HGHE with PCMs are robust and resilient alternatives for air conditioning.

References Powered by Scopus

Greenhouse gas emission savings of ground source heat pump systems in Europe: A review

329Citations
N/AReaders
Get full text

Comparison between the energy performance of a ground coupled water to water heat pump system and an air to water heat pump system for heating and cooling in typical conditions of the European Mediterranean coast

164Citations
N/AReaders
Get full text

Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating

144Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Effective parameters on the performance of ground heat exchangers: A review of latest advances

55Citations
N/AReaders
Get full text

Advances in coupled use of renewable energy sources for performance enhancement of vapour compression heat pump: A systematic review of applications to buildings

26Citations
N/AReaders
Get full text

Role of phase change materials in backfilling of flat-panels ground heat exchanger

20Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Bottarelli, M., & Gallero, F. J. G. (2020). Energy analysis of a dual-source heat pump coupled with phase change materials. Energies, 13(11). https://doi.org/10.3390/en13112933

Readers over time

‘20‘21‘22‘23‘24‘25036912

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 13

76%

Researcher 2

12%

Professor / Associate Prof. 1

6%

Lecturer / Post doc 1

6%

Readers' Discipline

Tooltip

Engineering 11

61%

Energy 5

28%

Design 1

6%

Materials Science 1

6%

Save time finding and organizing research with Mendeley

Sign up for free
0