Abstract

We present a case of fatal cardiac tamponade that occurred in association with a peripherally inserted central catheter (PICC) inserted from the right antecubital fossa. Migration of the catheter from the right atrium within 24 h of insertion lead to the administration of a potassium-enriched sodium chloride solution into the pericardial space with the development of ST-segment elevation and progression to pulseless electrical activity and, subsequently, ventricular fibrillation. Although signs of tamponade were seen on echocardiography, we propose that myocardial hyperkalaemia from the diffusion of potassium through the epicardium accounted for some of the clinical picture. PICC lines carry a greater risk of migration because of the tip movement associated with arm abduction and, therefore, care must be taken to ensure that the catheter tip is correctly positioned to reduce this risk. When such catheters are used for intra-operative central venous access, we believe chest radiography is mandatory before fluid administration through the catheter, but that this is unnecessary when the catheter is being used solely for central venous pressure monitoring. The use of softer catheters may reduce the risk of vessel perforation. Once tamponade is suspected, all drugs and infusions administered via the catheter should be reviewed, the catheter aspirated and echocardiography performed urgently. This may be facilitated by the greater availability of limited bedside echocardiography within critical care units and theatre complexes. © The Board of Management and Trustees of the British Journal of Anaesthesia 2007. All rights reserved.

Figures

References Powered by Scopus

Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (SonoHeart) in critically ill patients

269Citations
N/AReaders
Get full text

The carina as a landmark in central venous catheter placement

169Citations
N/AReaders
Get full text

Emergency echocardiography to detect pericardial effusion in patients in PEA and near-PEA states

164Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Misplaced central venous catheters: Applied anatomy and practical management

164Citations
N/AReaders
Get full text

The Midline Catheter: A Clinical Review

129Citations
N/AReaders
Get full text

Imaging of the complications of peripherally inserted central venous catheters

112Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Orme, R. M. L. E., McSwiney, M. M., & Chamberlain-Webber, R. F. O. (2007). Fatal cardiac tamponade as a result of a peripherally inserted central venous catheter: A case report and review of the literature. British Journal of Anaesthesia, 99(3), 384–388. https://doi.org/10.1093/bja/aem181

Readers over time

‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘25036912

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 18

49%

Professor / Associate Prof. 12

32%

Researcher 5

14%

Lecturer / Post doc 2

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 38

79%

Nursing and Health Professions 7

15%

Arts and Humanities 2

4%

Neuroscience 1

2%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 1

Save time finding and organizing research with Mendeley

Sign up for free
0