Visual perception changes and optical stability after intracorneal ring segment implantation: Comparison between 3 months and 1 year after surgery

4Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

Abstract

Purpose: To prospectively evaluate intracorneal ring segment (ICRS) implantation on quality of life (QoL) of patients with keratoconus changes and identify factors responsible. Methods: Sixty-nine eyes of 42 keratoconus patients were implanted with the Keraring (Mediphacos, Belo Horizonte, Brazil). Best corrected visual acuity (BCVA), refraction, and steep keratometry were analyzed 3 months and 1 year after surgery. All patients self-administered the National Eye Institute Refractive Error Quality of life instrument at 2 time points: after having worn best correction for at least 30 days since evaluation (mean 4 months after surgery) and 1 year after surgery. To analyze if the use of the appropriate correction at 1 year follow up had any impact on visual acuity and V-QoL, patients were divided into 2 groups: group A (appropriate correction) and B (not appropriate correction). Results: After 1 year, QoL changes related to scales 'clarity of vision', 'near vision', and 'far vision'. Keratometric values, sphere, and spherical equivalent did not differ significantly between 3 months and 1 year postoperative. Cylinder increase was statistically but not clinically significant. Binocular BCVA did not change 1 year after surgery in group A and showed a clinically significant impairment in group B. A year after surgery, 18 patients did not use correction suggested by a physician 3 months after surgery. QoL was not statistically different 1 year after surgery between group A and group B. Conclusion: Our findings show that the way keratoconic patients see is difficult to analyze using only quantitative and 1-visit metrics. They highlight the importance of patients' self perception and performing longitudinal analysis to consider neural compensation to optical changes from surgery. © 2011 Paranhos et al, publisher and licensee Dove Medical Press Ltd.

Author supplied keywords

References Powered by Scopus

Keratoconus

2702Citations
N/AReaders
Get full text

Intracorneal ring segments for keratoconus correction: Long-term follow-up

208Citations
N/AReaders
Get full text

Intracorneal ring segments in ectatic corneal disease - a review

170Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The impact of keratoconus treatment with the athens protocol (Partial topography-guided photorefractive keratectomy combined with higher-fluence corneal collagen cross-linking) on quality of life: A long-term study

15Citations
N/AReaders
Get full text

Clinical outcomes of femtosecond laser⇓assisted implantation of asymmetric ICRS in keratoconus with no coincidence of topographic and comatic axes

8Citations
N/AReaders
Get full text

Challenges in using both eyes of the same patient when evaluating the results after implantation of intrastromal corneal ring segments

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Paranhos, J. de F. S., Ávila, M. P., Paranhos, A., & Schor, P. (2011). Visual perception changes and optical stability after intracorneal ring segment implantation: Comparison between 3 months and 1 year after surgery. Clinical Ophthalmology, 5(1), 1057–1062. https://doi.org/10.2147/OPTH.S23147

Readers over time

‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘2401234

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 12

71%

Professor / Associate Prof. 3

18%

Lecturer / Post doc 1

6%

Researcher 1

6%

Readers' Discipline

Tooltip

Medicine and Dentistry 16

80%

Nursing and Health Professions 2

10%

Computer Science 1

5%

Psychology 1

5%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 1

Save time finding and organizing research with Mendeley

Sign up for free
0