Laboratory Scale Experimental Study of Foam Suppression on Smouldering Combustion of a Tropical Peat

12Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Solving peat fires problem continues to be a constant struggle in Indonesia as more hotspots are identified during the dry seasons. A number of research has been carried out to understand the most sufficient way to suppress peat fires using a range of different methods. This research was focused on the suppression of peat fire by using foaming-based suppression agent in the laboratory scale experiments. Experiments were carried out to explore the effect of foam suppression system on tropical peat fires. A solution of Class A Foam with a concentration of 3% was used to suppress Kalimantan peat fire with a density of ±0.3g/cm3. Sample used in the experiments was taken from Tumbang Nusa Village, Pulang Pisau District, Central Kalimantan Province, with a coordinate of S: -3°47′34″, E: 113°55′15″. This experiment will explore how many foam layers of certain heights are needed in order to extinguish peat fire. Peat sample was put in a 10x10x10 cm3 reactor, where a coil heater was turned on at 80 - 100W for 30 minutes to initiate a smouldering front. A set of type K thermocouples and infrared thermographs were used to explore the suppression mechanism that occurs. As the smouldering front moved away from the igniter to the other end of the reactor, foam with different thickness was poured on top of the peat to explore the effect of varying thickness on the suppression of peat fire. From the series of experiments, it was observed that there was a correlation between the thickness of the foam layer and the suppression of peat fires. The thickness of 10cm was found to be the most effective in terms of time at extinguishing peat fire. An average amount of 3.8L of foam per kilogram of Kalimantan peat was needed to extinguish peat fire. It was also found that the average amount of water needed to suppress peat fire using foam method was 3.4L/kg.

Author supplied keywords

References Powered by Scopus

Smoldering combustion

168Citations
N/AReaders
Get full text

Experimental study of the effect of water spray on the spread of smoldering in Indonesian peat fires

44Citations
N/AReaders
Get full text

Hydrophilic and hydrophobic characteristics of dry peat

26Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Review of the Transition From Smouldering to Flaming Combustion in Wildfires

87Citations
N/AReaders
Get full text

Can rain suppress smoldering peat fire?

31Citations
N/AReaders
Get full text

Laboratory study on the suppression of smouldering peat wildfires: effects of flow rate and wetting agent

18Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ratnasari, N. G., Dianti, A., Palamba, P., Ramadhan, M. L., Prayogo, G., Pamitran, A. S., & Nugroho, Y. S. (2018). Laboratory Scale Experimental Study of Foam Suppression on Smouldering Combustion of a Tropical Peat. In Journal of Physics: Conference Series (Vol. 1107). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/1107/5/052003

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

53%

Lecturer / Post doc 3

20%

Researcher 3

20%

Professor / Associate Prof. 1

7%

Readers' Discipline

Tooltip

Engineering 5

42%

Energy 3

25%

Chemical Engineering 2

17%

Agricultural and Biological Sciences 2

17%

Save time finding and organizing research with Mendeley

Sign up for free