Long-term bending creep behavior of thin-walled CFRP tendon pretensioned spun concrete poles

29Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

This paper discusses the long-term behavior of a series of highly-loaded, spun concrete pole specimens prestressed with carbon fiber-reinforced polymer (CFRP) tendons, which were subjected to outdoor four-point bending creep tests since 1996 in the frame of collaboration with the Swiss precast concrete producer, SACAC (Società Anonima Cementi Armati Centrifugati). The 2 m span cylindrical beams studied are models for lighting poles produced for the last 10 years and sold on the European market. Five thin-walled pole specimens were investigated (diameter: 100 mm; wall-thickness: 25-27 mm). All specimens were produced in a pretensioning and spinning technique and were prestressed by pultruded CFRP tendons. Initially, two reference pole specimens were tested in quasi-static four-point bending to determine the short-term failure moment and to model the short-term flexural behavior. Then, three pole specimens were loaded to different bending creep moments: while the lowest loaded specimen was initially uncracked, the second specimen was loaded with 50% of the short-term bending failure moment and exhibited cracking immediately after load introduction. The highest loaded pole specimen sustained a bending moment of 72% of the short-term bending failure moment for 16.5 years before failing in July 2013, due to the bond failure of the tendons,which led to local crushing of the high-performance spun concrete (HPSC). Besides this, long-term monitoring of the creep tests has shown a limited time- and temperature-dependent increase of the deflections over the years, mainly due to the creep of the concrete. A concrete creep-based model allowed for the calculation of the long-term bending curvatures with reasonable accuracy. Furthermore, the pole specimens showed crack patterns that were stable over time and minimal slippage of the tendons with respect to the pole's end-faces for the two lower load levels. The latter proves the successful and durable anchorage of these novel CFRP prestressing tendons in thin-walled, precast concrete members under realistic long-term service loads. © 2014 by the authors.

Cite

CITATION STYLE

APA

Terrasi, G. P., Meier, U., & Affolter, C. (2014). Long-term bending creep behavior of thin-walled CFRP tendon pretensioned spun concrete poles. Polymers, 6(7), 2065–2081. https://doi.org/10.3390/polym6072065

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free