Safety and effectiveness comparison of a new cohesive ophthalmic viscosurgical device

3Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.
Get full text

Abstract

To evaluate the safety and effectiveness of a new cohesive ophthalmic viscosurgical device (OVD) (StableVisc) compared with a marketed cohesive OVD (ProVisc) in patients undergoing cataract surgery.Setting:22 sites in the United States.Design:Prospective multicenter controlled double-masked and randomized 1:1 (StableVisc:ProVisc; stratified by site, age group, and cataract severity).Methods:Adults (≥45 years) with age-related noncomplicated cataract considered amenable to treatment with standard phacoemulsification cataract extraction and intraocular lens implantation were included. Patients were randomized to receive either StableVisc or ProVisc during standard cataract surgery. Postoperative visits occurred at 6 hours, 24 hours, 7 days, 1 month, and 3 months. The primary effectiveness outcome was the change in endothelial cell density (ECD) from baseline to 3 months. The primary safety endpoint was the proportion of patients who experienced at least 1 intraocular pressure (IOP) measurement ≥30 mm Hg at any follow-up visit. Noninferiority between the devices was tested. Inflammation and adverse events were evaluated.Results:390 patients were randomized; 187 patients with StableVisc and 193 patients with ProVisc completed the study. StableVisc was noninferior to ProVisc in mean ECD loss from baseline to 3 months (17.5% and 16.9%, respectively). StableVisc was noninferior to ProVisc in the proportion of patients with postoperative IOP ≥30 mm Hg at any follow-up visit (5.2% and 8.2%, respectively).Conclusions:The StableVisc cohesive OVD, which provides both mechanical and chemical protection, was safe and effective when used in cataract surgery and provides surgeons with a new cohesive OVD.

References Powered by Scopus

Standardization of uveitis nomenclature for reporting clinical data. Results of the first international workshop

3701Citations
N/AReaders
Get full text

The hygroscopic properties of dicarboxylic and multifunctional acids: Measurements and UNIFAC predictions

412Citations
N/AReaders
Get full text

Risk factors for corneal endothelial injury during phacoemulsification

311Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Comment on: Safety and effectiveness comparison of a new cohesive ophthalmic viscosurgical device

0Citations
N/AReaders
Get full text

Reply: Safety and effectiveness comparison of a new cohesive ophthalmic viscosurgical device

0Citations
N/AReaders
Get full text

Physical Characteristics, Clinical Application, and Side Effects of Viscoelastics in Ophthalmology

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Packer, M., Shultz, M., Loden, J., & Lau, G. (2023). Safety and effectiveness comparison of a new cohesive ophthalmic viscosurgical device. Journal of Cataract and Refractive Surgery, 49(8), 804–811. https://doi.org/10.1097/j.jcrs.0000000000001201

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

100%

Readers' Discipline

Tooltip

Chemistry 2

67%

Pharmacology, Toxicology and Pharmaceut... 1

33%

Save time finding and organizing research with Mendeley

Sign up for free