Performance and reference intervals of thrombin generation test: results from the Brazilian longitudinal study of adult health (ELSA-Brasil). A cross-sectional study

4Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND: The thrombin generation test (TGT) has shown promise for investigation of hemorrhag-ic and thrombotic diseases. However, despite its potential, it still needs standardization. Moreover, few studies have established reference values for TGT parameters. In Brazil, these values have not yet been established. OBJECTIVE: To determine TGT performance and reference intervals for TGT parameters in healthy indi-viduals. DESIGN AND SETTING: Cross-sectional study conducted among participants in the Brazilian Longitudinal Study of Adult Health (Estudo Longitudinal de Saúde do Adulto, ELSA-Brasil). METHODS: The reference sample consisted of 620 healthy individuals. The calibrated automated throm-bogram (CAT) method, under low and high tissue factor (TF) conditions, was used to assess thrombin generation. Test performance was analyzed using intra and interassay coefficients of variation (CV) and reference intervals were calculated using the nonparametric method proposed by the International Fed-eration of Clinical Chemistry and the Clinical and Laboratory Standards Institute. RESULTS: The intraassay CV ranged from 1.4% to 2.2% and the interassay CV, 6.8% to 14.7%. The reference intervals for TGT parameters under low and high TF conditions were, respectively: lagtime: 3.0-10.3 and 1.4-3.7 min; endogenous thrombin potential (ETP): 1134.6-2517.9 and 1413.6-2658.0 nM.min; normalized ETP: 0.6-1.3 and 0.7-1.4; peak: 103.2-397.7 and 256.4-479.0 nM; normalized peak: 0.3-1.3 and 0.7-1.2; and time-to-peak: 5.6-16.0 and 3.4-6.7 min. These parameters were categorized relative to sex. CONCLUSION: TGT performance was adequate and the proposed reference intervals were similar to those of other studies. Our findings may be useful for consolidating the TGT, through contributing to its standardization and validation.

References Powered by Scopus

Calibrated automated thrombin generation measurement in clotting plasma

1255Citations
N/AReaders
Get full text

Brazilian Longitudinal Study of Adult health (ELSA-Brasil): Objectives and design

578Citations
N/AReaders
Get full text

Cohort profile: Longitudinal study of adult health (ELSA-Brasil)

447Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Mathematical models of coagulation—are we there yet?

3Citations
N/AReaders
Get full text

Multicenter analytical performance evaluation of the ST Genesia thrombin generation system

0Citations
N/AReaders
Get full text

Reference intervals and biological variation in parameters of the thrombin generation test in healthy individuals

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Rios, D. R. A., Barreto, S. M., Ferreira, L. G. R., Batista, T. R., Silva, A. P. F., de Oliveira Júnior, W. V., … Figueiredo, R. C. (2022). Performance and reference intervals of thrombin generation test: results from the Brazilian longitudinal study of adult health (ELSA-Brasil). A cross-sectional study. Sao Paulo Medical Journal, 140(3), 474–485. https://doi.org/10.1590/1516-3180.2021.0425.R1.07102021

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

100%

Readers' Discipline

Tooltip

Biochemistry, Genetics and Molecular Bi... 2

40%

Medicine and Dentistry 1

20%

Pharmacology, Toxicology and Pharmaceut... 1

20%

Mathematics 1

20%

Save time finding and organizing research with Mendeley

Sign up for free