An adaptive threshold image reconstruction algorithm of oil-water two-phase flow in electrical capacitance tomography system

0Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The subject investigated in this paper is the ECT system of 8-electrode oil-water two-phase flow, and the measuring principle is analysed. In ART image-reconstruction algorithm, an adaptive threshold image reconstruction is presented to improve quality of image reconstruction and calculating accuracy of concentration, and generally the measurement error is about 1%. Such method can well solve many defects that other measurement methods may have, such as slow speed, high cost, and poor security and so on. Therefore, it offers a new method for the concentration measurement of oil-water two-phase flow. © 2006 IOP Publishing Ltd.

Cite

CITATION STYLE

APA

Qin, M., Chen, D. Y., Wang, L. L., & Yu, X. Y. (2006). An adaptive threshold image reconstruction algorithm of oil-water two-phase flow in electrical capacitance tomography system. Journal of Physics: Conference Series, 48(1), 422–426. https://doi.org/10.1088/1742-6596/48/1/080

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free