Improvement of insertion loss and quality factor of flexural plate-wave-based alpha-fetoprotein biosensor using groove-type reflective grating structures

  • Lin C
  • Huang I
  • Lan J
3Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Conventional flexural plate-wave (FPW) transducers have limited applications in biomedical sensing due to their disadvantages such as high insertion loss and low quality factor. To overcome these shortcomings, we propose a FPW transducer on a low phase velocity insulator membrane (5-mu m-thick SiO2) with a novel groove-type reflective grating structure design. Additionally, a cystamine self-assembly monolayer and a glutaraldehyde cross-linking layer are implemented on the backside of the FPW device to immobilize alpha-fetoprotein (AFP) antibody. A FPW-based AFP biosensor with low detection limit (5 ng/mL) can be achieved and used to measure the extreme low concentration of AFP antigen in human serum for early detection of hepatocellular carcinoma. The proposed FPW-based AFP biosensor also demonstrates a very high quality factor (206), low insertion loss (-40.854 dB), low operating frequency (6.388 MHz), and high sensing linearity (90.7%). (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.

References Powered by Scopus

Self-assembled monolayers for biosensors

597Citations
N/AReaders
Get full text

Demonstration of a new protein fraction in serum from the human fetus

390Citations
N/AReaders
Get full text

Immunosensors: Technology and opportunities in laboratory medicine

233Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Development of an FPW biosensor with low insertion loss and high fabrication yield for detection of carcinoembryonic antigen

13Citations
N/AReaders
Get full text

Aluminum nitride Lamb wave piezoelectric resonators based on ultrathin silicon substrates

7Citations
N/AReaders
Get full text

Study of the Effect of the Operating Frequency of a GaN Lamb Wave Device to Viscosity and Protein Sensing

6Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lin, C.-Y., Huang, I.-Y., & Lan, J.-W. (2013). Improvement of insertion loss and quality factor of flexural plate-wave-based alpha-fetoprotein biosensor using groove-type reflective grating structures. Journal of Micro/Nanolithography, MEMS, and MOEMS, 12(1), 013017. https://doi.org/10.1117/1.jmm.12.1.013017

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

67%

Researcher 1

33%

Readers' Discipline

Tooltip

Engineering 3

100%

Save time finding and organizing research with Mendeley

Sign up for free