Pulmonary MR perfusion at 3.0 Tesla using a blood pool contrast agent: Initial results in a swine model

15Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To prospectively evaluate the technical feasibility of a highly accelerated pulmonary MR perfusion protocol at 3.0T using a blood pool contrast agent in a swine model. Materials and Methods: Twelve pigs underwent time-resolved pulmonary MR angiography (MRA) on a 3.0T MR system under anesthesia and controlled mechanical ventilation. After intravenous injection of 0.05 mmol/kg of Gadomer-17 at 4 mL/second, a fast time-resolved MRA sequence with temporal echo-sharing (three segmented k-space) and highly accelerated parallel acquisition was used to acquire 3D data sets with an in-plane resolution of 1 × 1 mm2 (slice thickness = 6 mm) and temporal resolution of one second. Image quality was evaluated independently by two radiologists, and quantitative analysis of perfusion parameters was performed using pre-released perfusion software. Results: All studies were identified by both readers as having diagnostic image quality (range = 2-3, median = 3) and there was excellent interobserver agreement (κ = 0.89; 95% CI = 0.83, 0.95). A quantitative analysis of perfusion indices was performed, with excellent overall goodness-of-fit (χ2 value = 1.4, degree of freedom (DF) = 1). Successfully derived perfusion parameters included the time to peak (TTP, 5.1 ± 0.7 second), mean transit time (MTT, 6.6 ± 0.9 second), maximal signal intensity (MSI, 1051.2 ± 718.9 arbitrary units [A.U.]), and maximal upslope of the curve (MUS, 375.9 ± 263.4 A.U./second). Conclusion: 3.0T pulmonary MR perfusion using a blood pool contrast agent in a swine model is feasible. The higher available signal-to-noise ratio (SNR) at 3.0T and the high T1 relaxivity of Gadomer-17 effectively support highly accelerated parallel acquisition, and improve the performance of time-resolved pulmonary MRA. © 2006 Wiley-Liss, Inc.

Cite

CITATION STYLE

APA

Nael, K., Saleh, R., Nyborg, G. K., Fonseca, C. G., Weinmann, H. J., Laub, G., & Finn, J. P. (2007). Pulmonary MR perfusion at 3.0 Tesla using a blood pool contrast agent: Initial results in a swine model. Journal of Magnetic Resonance Imaging, 25(1), 66–72. https://doi.org/10.1002/jmri.20799

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free