Spread-out Bragg peak proton FLASH irradiation using a clinical synchrocyclotron: Proof of concept and ion chamber characterization

50Citations
Citations of this article
61Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: The purpose of this work is to (a) demonstrate the feasibility of delivering a spread-out Bragg peak (SOBP) proton beam in ultra-high dose rate (FLASH) using a proton therapy synchrocyclotron as a major step toward realizing an experimental platform for preclinical studies, and (b) evaluate the response of four models of ionization chambers in such a radiation field. Methods: A clinical Mevion HYPERSCAN® synchrocyclotron was adjusted for ultra-high dose rate proton delivery. Protons with nominal energy of 230 MeV were delivered in pulses with temporal width ranging from 12.5 μs to 24 μs spanning from conventional to FLASH dose rates. A boron carbide absorber and a range modulator block were placed in the beam path for range modulation and creating an SOBP dose profile. The radiation field was defined by a brass aperture with 11 mm diameter. Two Faraday cups were used to determine the number of protons per pulse at various dose rates. The dosimetric response of two cylindrical (IBA CC04 and CC13) and two plane-parallel (IBA PPC05 and PTW Advanced Markus®) ionization chambers were evaluated. The dose rate was measured using the plane-parallel ionization chambers. The integral depth dose (IDD) was measured with a PTW Bragg Peak® ionization chamber. The lateral beam profile was measured with EBT-XD radiochromic film. Monte Carlo simulation was performed in TOPAS as the secondary check for the measurements and as a tool for further optimization of the range modulators’ design. Results: Faraday cups measurement showed that the maximum protons per pulse is 39.9 pC at 24 μs pulse width. A good agreement between the measured and simulated IDD and lateral beam profiles was observed. The cylindrical ionization chambers showed very high ion recombination and deemed not suitable for absolute dosimetry at ultra-high dose rates. The average dose rate measured using the PPC05 ionization chamber was 163 Gy/s at the pristine Bragg peak and 126 Gy/s at 1 cm depth for the SOBP beam. The SOBP beam range and modulation were measured 24.4 mm and 19 mm, respectively. The pristine Bragg peak beam had 25.6 mm range. Simulation results showed that the IDD and profile flatness can be improved by the cavity diameter of the range modulator and the number of scanned spots, respectively. Conclusions: Feasibility of delivering protons in an SOBP pattern with >100 Gy/s average dose rate using a clinical synchrocyclotron was demonstrated. The dose heterogeneity can be improved through optimization of the range modulator and number of delivered spots. Plane-parallel chambers with smaller gap between electrodes are more suitable for FLASH dosimetry compared to the other ion chambers used in this work.

References Powered by Scopus

Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice

995Citations
N/AReaders
Get full text

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

846Citations
N/AReaders
Get full text

The Advantage of FLASH Radiotherapy Confirmed in Mini-pig and Cat-cancer Patients

569Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Ultra-high dose rate dosimetry: Challenges and opportunities for FLASH radiation therapy

114Citations
N/AReaders
Get full text

Comparison of flash proton entrance and the spread-out bragg peak dose regions in the sparing of mouse intestinal crypts and in a pancreatic tumor model

81Citations
N/AReaders
Get full text

The current status of preclinical proton FLASH radiation and future directions

70Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Darafsheh, A., Hao, Y., Zhao, X., Zwart, T., Wagner, M., Evans, T., … Zhao, T. (2021). Spread-out Bragg peak proton FLASH irradiation using a clinical synchrocyclotron: Proof of concept and ion chamber characterization. Medical Physics, 48(8), 4472–4484. https://doi.org/10.1002/mp.15021

Readers' Seniority

Tooltip

Researcher 12

50%

PhD / Post grad / Masters / Doc 11

46%

Professor / Associate Prof. 1

4%

Readers' Discipline

Tooltip

Physics and Astronomy 11

52%

Medicine and Dentistry 5

24%

Engineering 4

19%

Computer Science 1

5%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 33

Save time finding and organizing research with Mendeley

Sign up for free