Hepatic Resection Using a Water Jet Dissector

61Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The mortality and morbidity in major hepatic resection is often related to hemorrhage. A high pressure, high velocity water jet has been developed and has been utilized to assist in hepatic parenchymal transection. Sixty-seven major hepatic resections were performed for solid hepatic tumors. The tissue fracture technique was used in 51 patients (76%), and the water jet dissector was used predominantly in 16 patients (24%). The extent of hepatic resection using each technique was similar. The results showed no difference in operative duration (p=.499). The mean estimated blood loss using the water jet was 1386 ml, and tissue fracture technique 2450 ml (p=.217). Transfusion requirements were less in the water jet group (mean 2.0 units) compared to the tissue fracture group (mean 5.2 units); (p=.023). Results obtained with the new water dissector are encouraging. The preliminary results suggest that blood loss may be diminished. © 1993, Harwood Academic Publishers GmbH.

Cite

CITATION STYLE

APA

Baer, H. U., Stain, S. C., Guastella, T., Maddern, G. J., & Blumgart, L. H. (1993). Hepatic Resection Using a Water Jet Dissector. HPB Surgery, 6(3), 189–198. https://doi.org/10.1155/1993/82362