Bond strength of soft denture liners following immersion of denture cleanser

5Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This study investigated the effect of a denture cleanser on tensile bond strength of acrylic and silicone-based soft denture liners. The denture liners investigated were an acrylic-based, heat-cured (Vertex soft), an acrylic-based, auto-cured (Coe soft), a silicon-based, heat-cured (Molloplast-B) and a silicon-based, auto-cured (Mollosil plus). Soft liner specimens were 10×10×3 mm in size and processed for testing according to manufacturers' instructions between 2 polymethyl methacrylate (PMMA) blocks. Specimens were stored for 1 day, 1 week and 1, 3 and 6 months in water and Polident at 37°C. Tensile bond strength was measured using a universal testing machine (Testometric Micro 500) at a crosshead speed of 20 mm/min (n=10 specimens per experimental group). ANOVA and Tukey HSD methods were used to analyze the data (α=.05). The results indicated that the tensile bond strength of all lining materials decreased with storage duration (both water and Polident), and no difference between treatments. © 2006 Taylor and Francis Group, LLC.

Cite

CITATION STYLE

APA

Meşe, A. (2006). Bond strength of soft denture liners following immersion of denture cleanser. Biotechnology and Biotechnological Equipment, 20(3), 184–191. https://doi.org/10.1080/13102818.2006.10817399