X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT

7Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Soft tissue images from portable cone beam computed tomography (CBCT) scanners can be used for diagnosis and detection of tumor, cancer, intracerebral hemorrhage, and so forth. Due to large field of view, X-ray scattering which is the main cause of artifacts degrades image quality, such as cupping artifacts, CT number inaccuracy, and low contrast, especially on soft tissue images. In this work, we propose the X-ray scatter correction method for improving soft tissue images. The X-ray scatter correction scheme to estimate X-ray scatter signals is based on the deconvolution technique using the maximum likelihood estimation maximization (MLEM) method. The scatter kernels are obtained by simulating the PMMA sheet on the Monte Carlo simulation (MCS) software. In the experiment, we used the QRM phantom to quantitatively compare with fan-beam CT (FBCT) data in terms of CT number values, contrast to noise ratio, cupping artifacts, and low contrast detectability. Moreover, the PH3 angiography phantom was also used to mimic human soft tissues in the brain. The reconstructed images with our proposed scatter correction show significant improvement on image quality. Thus the proposed scatter correction technique has high potential to detect soft tissues in the brain.

References Powered by Scopus

GEANT4 - A simulation toolkit

20625Citations
N/AReaders
Get full text

Flat-detector computed tomography (FD-CT)

278Citations
N/AReaders
Get full text

Review of portable CT with assessment of a dedicated head CT scanner

103Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Cone-beam CT in paediatric dentistry: DIMITRA project position statement

205Citations
N/AReaders
Get full text

Truncation effect reduction for fast iterative reconstruction in cone-beam CT

3Citations
N/AReaders
Get full text

Image Quality Evaluation of a Digital Radiography System Made in Thailand

2Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Aootaphao, S., Thongvigitmanee, S. S., Rajruangrabin, J., Thanasupsombat, C., Srivongsa, T., & Thajchayapong, P. (2016). X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT. BioMed Research International, 2016. https://doi.org/10.1155/2016/3262795

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 12

60%

Researcher 5

25%

Lecturer / Post doc 2

10%

Professor / Associate Prof. 1

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 10

50%

Engineering 5

25%

Physics and Astronomy 4

20%

Computer Science 1

5%

Save time finding and organizing research with Mendeley

Sign up for free