Monoscopic imaging for intra-fraction motion management

0Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: Image-guidance allows for accurate positioning of spinal radiosurgery patients; however, due to long treatment times an accurate and efficient intra-fraction motion management is necessary. An analysis tool, Snap Verification (SV, BrainLAB AG, Feldkirchen, Germany) has been implemented to monitor intra-fraction motion based on single oblique digital radiographs. We investigate the feasibility of the method in a clinical setting and its performance in detecting spinal radiosurgery patient movements in 3D space. Materials and Methods: Intra-fraction motion for initial group of patients was monitored using stereoscopic kV X-ray images obtained before each treatment beam or arc. The reference intra-fraction translations and rotations were quantified based on 6D fusion using 2D-3D registration algorithm. Then, 2D-2D analysis tool was applied to fuse individual 2D images to the corresponding DRRs, each time assuming the complementary image was not obtained. The results of 2D-3D (stereoscopic) and 2D-2D (monoscopic) methods were compared. For this initial investigation, the analysis was applied to 82 X-ray images. Results: The differences between monoscopic and stereoscopic estimates of translations were less than 1.0mm. To further assess the performance of SV, contingency tables were analyzed. For detecting 1.5mm movement, single image analysis with 1.2mm threshold maximizes Youden Index. Furthermore, when monoscopic threshold is set to 1.2mm with the goal of detecting 1.5mm or larger 3D movements, the following results are observed - sensitivity 89%, specificity 79%, positive predictive value 59% and negative predictive value 95%. Conclusions: Monoscopic imaging is suitable for intra-fraction motion detection. Appropriate thresholds should be utilized for acceptable rate of false positive and false negative predictions. For 1.5mm 3D movement detection 1.2mm 2D analysis threshold results to greater than 95% negative predictive value. Large scale study has been initiated for better understanding the performance of the method to detect intra-fraction patient motion. © 2009 Springer-Verlag.

Author supplied keywords

Cite

CITATION STYLE

APA

Agazaryan, N., Tenn, S., Selch, M., Rehs, J., Erbel, S., & Remmert, G. (2009). Monoscopic imaging for intra-fraction motion management. In IFMBE Proceedings (Vol. 25, pp. 1057–1059). Springer Verlag. https://doi.org/10.1007/978-3-642-03474-9_297

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free