A new spirometry-based algorithm to predict occupational pulmonary restrictive impairment

6Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Spirometry is often included in workplace-based respiratory surveillance programmes but its performance in the identification of restrictive lung disease is poor, especially when the prevalence of this condition is low in the tested population. Aims: To improve the specificity (Sp) and positive predictive value (PPV) of current spirometry-based algorithms in the diagnosis of restrictive pulmonary impairment in the workplace and to reduce the proportion of false positives findings and, as a result, unnecessary referrals for lung volume measurements.Methods: We re-analysed two studies of hospital patients, respectively used to derive and validate a recommended spirometry-based algorithm [forced vital capacity (FVC) < 85% predicted and forced expiratory volume in 1 s (FEV1)/FVC > 55%] for the recognition of restrictive pulmonary impairment. We used true lung restrictive cases as a reference standard in 2×2 contingency tables to estimate sensitivity (Sn), Sp and PPV and negative predictive values for each diagnostic cut-off. We simulated a working population aged <65 years and with a disease prevalence ranging 1-10% and compared our best algorithm with those previously reported using receiver operating characteristic curves. Results: There were 376 patients available from the two studies for inclusion. Our best algorithm (FVC < 70% predicted and FEV1/FVC ≥ 70%) achieved the highest Sp (96%) and PPV (67 and 15% for a disease prevalence of 10 and 1%, respectively) with the lowest proportion of false positives (4%); its high Sn (71%) predicted the highest proportion of correctly classified restrictive cases (91%). Conclusions: Our new spirometry-based algorithm may be adopted to accurately exclude pulmonary restriction and to possibly reduce unnecessary lung volume testing in an occupational health setting.

References Powered by Scopus

Spirometric reference values from a sample of the general U.S. Population

3640Citations
N/AReaders
Get full text

Diagnostic spirometry in primary care: Proposed standards for general practice compliant with American Thoracic Society and European Respiratory Society recommendations

181Citations
N/AReaders
Get full text

A spirometry-based algorithm to direct lung function testing in the pulmonary function laboratory

72Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Non-invasive techniques to assess restrictive lung disease in workers exposed to free crystalline silica

5Citations
N/AReaders
Get full text

Physiology and Biomarkers for Surveillance of Occupational Lung Disease

1Citations
N/AReaders
Get full text

Functional status in patients undergoing lung resection

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

De Matteis, S., Iridoy-Zulet, A. A., Aaron, S., Swann, A., & Cullinan, P. (2016). A new spirometry-based algorithm to predict occupational pulmonary restrictive impairment. Occupational Medicine, 66(1), 50–53. https://doi.org/10.1093/occmed/kqv127

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

80%

Researcher 2

20%

Readers' Discipline

Tooltip

Medicine and Dentistry 7

64%

Nursing and Health Professions 2

18%

Social Sciences 1

9%

Agricultural and Biological Sciences 1

9%

Save time finding and organizing research with Mendeley

Sign up for free