A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait

40Citations
Citations of this article
65Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Conventional total knee replacement designs show high success rates but in the long term, the stiff metal components may affect bone quality of the distal femur. In this study we introduce an all-polymer total knee replacement device containing a PEEK femoral component on an UHMWPE tibial implant and study its mechanical integrity, fixation, and stress shielding of the periprosthetic femur. Methods: The implant was analysed in finite element simulations of level gait, adopted from the ISO 14243-1 standard. Mechanical integrity of the implant and underlying cement mantle were tested, and the fixation strength of the cement-implant interface was studied. Stress shielding was assessed based on strain energy density distributions in the distal femur. We compared PEEK and CoCr implants for mechanical performance and fixation, and compared both versions against an intact case to determine the change in bone strain energy density. Results: The mechanical integrity of the PEEK and CoCr components was similar in magnitude, but differences in stress patterns were found. Moreover, the cement mantle was loaded more heavily in the CoCr configuration. Under similar interface properties, the CoCr-cement interface was more at risk of failure than the PEEK-cement interface. The bone strain energy density distribution of the PEEK implant was similar to the intact case, while the CoCr implant showed signs of stress shielding, and a different distribution than the intact and PEEK models. Conclusions: During gait, the PEEK femoral component performed similarly to CoCr, with no added risk for the cement mantle. The reduction in stress shielding for PEEK was evident and confirms the potential reduction in long-term loss of bone stock for this all-polymer knee implant.

References Powered by Scopus

PEEK biomaterials in trauma, orthopedic, and spinal implants

1966Citations
N/AReaders
Get full text

Properties of acrylic bone cement: State of the art review

670Citations
N/AReaders
Get full text

The elastic properties of trabecular and cortical bone tissues are similar: Results from two microscopic measurement techniques

462Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Developments of PEEK (Polyetheretherketone) as a biomedical material: A focused review

141Citations
N/AReaders
Get full text

3D printed porous PEEK created via fused filament fabrication for osteoconductive orthopaedic surfaces

79Citations
N/AReaders
Get full text

Total knee arthroplasty application of polyetheretherketone and carbon-fiber-reinforced polyetheretherketone: A review

79Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

de Ruiter, L., Janssen, D., Briscoe, A., & Verdonschot, N. (2017). A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait. Journal of Experimental Orthopaedics, 4(1). https://doi.org/10.1186/s40634-017-0078-4

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 25

76%

Researcher 5

15%

Professor / Associate Prof. 2

6%

Lecturer / Post doc 1

3%

Readers' Discipline

Tooltip

Engineering 15

43%

Medicine and Dentistry 15

43%

Materials Science 4

11%

Philosophy 1

3%

Save time finding and organizing research with Mendeley

Sign up for free