Intrafraction displacement of prone versus supine prostate positioning monitored by real-time electromagnetic tracking

12Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Implanted radiofrequency transponders were used for real-time monitoring of the intrafraction prostate displacement between patients in the prone position and the same patients in the supine position. Thirteen patients had three transponders implanted transperineally and were treated prone with a custom-fitted thermoplastic immobilization device. After collecting data from the last fraction, patients were realigned in the supine position and the displacements of the transponders were monitored for 5-7 minutes. Fourier transforms were applied to the data from each patient to determine periodicity and its amplitude. To remove auto correlation from the stream of displacement data, the distribution of short-term and long-term velocity components were calculated from Poincaré plots of paired sequential vector displacements. The mean absolute displacement was significantly greater prone than supine in the superior-inferior (SI) plane (1.2 ± 0.6 mm vs. 0.6 ± 0.4 mm, p= 0.015), but not for the lateral or anterior-posterior (AP) planes. Displacements were least in the lateral direction. Fourier analyses showed the amplitude of respiratory oscillations was much greater for the SI and AP planes in the prone versus the supine position. Analysis of Poincaré plots confirmed greater short-term variance in the prone position, but no difference in the long-term variance. The centroid of the implanted transponders was offset from the treatment isocenter by > 5 mm for 1.9% of the time versus 0.8% of the time for supine. These results confirmed significantly greater net intrafraction prostate displacement of patients in the prone position than in the supine position, but most of the difference was due to respiration-induced motion that was most pronounced in the SI and AP directions. Because the respiratory motion remained within the action threshold and also within our 5 mm treatment planning margins, there is no compelling reason to choose one treatment position over the other.

References Powered by Scopus

Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy

440Citations
N/AReaders
Get full text

Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer

383Citations
N/AReaders
Get full text

Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions

187Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Real-time intrafraction motion monitoring in external beam radiotherapy

164Citations
N/AReaders
Get full text

MRI-guided prostate adaptive radiotherapy – A systematic reviewMRI-linac and prostate motion review

126Citations
N/AReaders
Get full text

Review of ultrasound image guidance in external beam radiotherapy part II: Intra-fraction motion management and novel applications

91Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Butler, W. M., Merrick, G. S., Reed, J. L., Murray, B. C., & Kurko, B. S. (2013). Intrafraction displacement of prone versus supine prostate positioning monitored by real-time electromagnetic tracking. Journal of Applied Clinical Medical Physics, 14(2), 198–208. https://doi.org/10.1120/jacmp.v14i2.4141

Readers over time

‘14‘15‘16‘17‘18‘19‘20‘21‘24‘2502468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

67%

Professor / Associate Prof. 2

17%

Lecturer / Post doc 1

8%

Researcher 1

8%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

40%

Physics and Astronomy 5

33%

Computer Science 2

13%

Engineering 2

13%

Save time finding and organizing research with Mendeley

Sign up for free
0