Endo/epicardial ablation of ventricular arrhythmias with contact force-sensing catheters in arrhythmogenic right ventricular dysplasia/cardiomyopathy

5Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: To control ventricular arrhythmia in arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C), ablation may be required both from the endocardial and epicardial side. In this study, we analyzed the results of contact force-sensing (CFS) catheters in the endo/epicardial ablation of ventricular arrhythmias in ARVD/C. Methods: We included 17 patients with ARVD/C, 5 of whom had premature ventricular contractions (PVC), and the rest of them were admitted with a ventricular tachycardia (VT) storm, between September 2014 and October 2016. We divided patients into two groups: the PVC and VT groups. Irrigated CFS catheters (Smart Touch, Biosense Webster, Inc.) were utilized in all procedures. Results: In the PVC group, the mean ratio of PVC during the 24-hour Holter monitoring was 31.8±7.6%. The mean contact force during mapping and ablation in the right ventricle was 13±1.2 and 12.8±1.9 grams, respectively. The mean follow-up duration was 15±3.1 months for the PVC group. The left ventricular ejection fraction improved in all patients (52.8±10%). All patients in the VT group underwent endo/epicardial ablation, except one. The mean contact force during the endocardium and epicardium mapping was 12.5±1.2 and 12.5±4.6 grams, respectively. The mean contact force during ablation for the endocardium and epicardium was 12.1±1.4 and 12.8±1.9 grams, respectively. All clinical and non-clinical VTs were ablated successfully, except in 2 patients who still had non-clinical VTs. The mean follow-up was 15.5±4.5 months. None of the VT patients experienced electrical storm or death. Two patients had single shock, and 1 patient had two shocks during the follow-up. Conclusion: Endo/epicardial ablation of ventricular arrhythmias with CFS catheters in ARVD/C seems to be promising. (Anatol J Cardiol 2019; 21: 187-95).

Cite

CITATION STYLE

APA

Aras, D., Özcan, F., Çay, S., Özeke, Ö., Kara, M., & Topaloğlu, S. (2019). Endo/epicardial ablation of ventricular arrhythmias with contact force-sensing catheters in arrhythmogenic right ventricular dysplasia/cardiomyopathy. Anatolian Journal of Cardiology, 21(4), 187–195. https://doi.org/10.14744/AnatolJCardiol.2018.58534

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free