Differences in complication rates among the centres in the SPACE study

68Citations
Citations of this article
43Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Introduction: Despite the high grade of standardisation of study protocols, there is still room for variability among the centres in specific treatment aspects. We evaluated the treatment risk in stent-protected angioplasty of the carotid versus endarterectomy (SPACE) associated with the specific patient enrolment rates of the centres. Materials and methods: The analysed endpoints were ipsilateral stroke or death [primary outcome event (pOE)] and any stroke or death [secondary outcome event (sOE)] until 30 days after treatment. A binary logistic regression analysis with random effects was performed separately for each treatment arm. The centres were secondarily categorised in three classes: I) ≥25 patients enrolled, II) ten to 24 patients and III) <10 patients and a hierarchic log linear model was fitted to test the three-way interaction of treatment, number of patients per class and outcome. Results: The random effects logistic regression analysis in the carotid artery stenting (CAS) arm proved a significant increase in pOE with decreasing number of patients enrolled (-0.0190 ± 0.0085, p = 0.025, deviance 35.7 with 32 df), whereas no such effect was found in the carotid endartectomy (CEA) arm (-0.010 ± 0.008, p = 0.24, deviance 39.78 with 32 df). In the log linear model, there was a significant interaction between treatment, number of patients per centre and sOE (p = 0.023). The odds ratios for sOE in the enrolment classes (CAS vs. CEA) were 0.98 (95% CI 0.50-1.94, p = 0.95) for class I, 1.13 (95% CI 0.47-2.77, p = 0.77) for class II and 11.56 (95% CI 1.40-253.45, p = 0.01) for class III centres. Conclusion: Despite rigorous standardisation and quality requirements for operator qualification, there seemed to be a decrease in complication rate with increasing patient enrolment numbers in the CAS arm while this signal could not be detected in the CEA arm of SPACE. © 2008 Springer-Verlag.

Cite

CITATION STYLE

APA

Fiehler, J., Jansen, O., Berger, J., Eckstein, H. H., Ringleb, P. A., & Stingele, R. (2008). Differences in complication rates among the centres in the SPACE study. Neuroradiology, 50(12), 1049–1053. https://doi.org/10.1007/s00234-008-0459-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free