Accuracy of a patient-specific 3D-printed drill guide for placement of bicortical screws in atlantoaxial ventral stabilization in dogs

5Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

Atlantoaxial instability (AAI) in dogs refers to abnormal motion at the C1-C2 articulation due to congenital or developmental anomalies. Surgical treatment options for AAI include dorsal and ventral stabilization techniques. Ventral stabilization techniques commonly utilize transarticular and vertebral body screws or pins. However, accurate screw insertion into the vertebrae of C1 and C2 is difficult because of the narrow safety corridors. This study included 10 mixed dogs, 1 Pomeranian, and 1 Shih-Tzu cadaver. All dogs weighed <10 kg. Each specimen was scanned using computed tomography (CT) from the head to the 7th cervical vertebrae. This study used 12 bone models and 6 patient-specific drill guides. Bone models were made using CT images and drill guides were created through a CAD (computer-aided design) program. A total of six cortical screws were used for each specimen. Two screws were placed at each of the C1, C2 cranial, and C2 caudal positions. Postoperative CT images of the cervical region were obtained. The degree of cortex breaching and angle and bicortical status of each screw was evaluated. The number of screws that did not penetrate the vertebral canal was higher in the guided group (33/36, 92%) than in the control group (20/36, 56%) (P = 0.003). The screw angles were more similar to the reference angle compared to the control group. The number of bicortically applied screws in the control group was 28/36 (78%) compared to 34/36 (94%) in the guided group. Differences between the preoperative plan and the length of the applied screw at the C1 and C2 caudal positions were determined by comparing the screw lengths in the guide group. The study results demonstrated that the use of a patient-specific 3D-printed drill guide for AAI ventral stabilization can improve the accuracy of the surgery. The use of rehearsal using bone models and a drilling guide may improve screw insertion accuracy.

References Powered by Scopus

Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques

166Citations
N/AReaders
Get full text

Risk factors affecting the outcome of surgery for atlantoaxial subluxation in dogs: 46 cases (1978-1998)

92Citations
N/AReaders
Get full text

Surgical Management of Atlantoaxial Subluxation in 23 Dogs

84Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Virtual Scoliosis Surgery Using a 3D-Printed Model Based on Biplanar Radiographs

5Citations
N/AReaders
Get full text

Ex vivo comparison of pin placement with patient-specific drill guides or freehand technique in canine cadaveric spines

3Citations
N/AReaders
Get full text

3D-Printing in Orthopedics

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Yu, Y., Kang, J., Kim, N., & Heo, S. (2022). Accuracy of a patient-specific 3D-printed drill guide for placement of bicortical screws in atlantoaxial ventral stabilization in dogs. PLoS ONE, 17(8 August). https://doi.org/10.1371/journal.pone.0272336

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

60%

Lecturer / Post doc 2

20%

Professor / Associate Prof. 1

10%

Researcher 1

10%

Readers' Discipline

Tooltip

Veterinary Science and Veterinary Medic... 6

43%

Medicine and Dentistry 4

29%

Agricultural and Biological Sciences 3

21%

Nursing and Health Professions 1

7%

Save time finding and organizing research with Mendeley

Sign up for free