Ultra-fast steady state free precession and its application to in vivo 1H morphological and functional lung imaging at 1.5 tesla

58Citations
Citations of this article
74Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose The speed limit for three-dimensional Fourier-encoded steady state free precession (SSFP) imaging is explored on a clinical whole body system and pushed toward a pulse repetition time (TR) close to or even below the 1 ms regime; in the following referred to as ultra-fast SSFP imaging. Methods To this end, contemporary optimization strategies, such as efficient gradient switching patterns, partial echoes, ramp sampling techniques, and a target-related design of excitation pulses were applied to explore the lower boundaries in TR for SSFP-based Cartesian imaging. Results Generally, minimal TR was limited in vivo by peripheral nerve stimulation, allowing a TR ∼1 ms for isotropic resolutions down to about 2 mm. As a result, ultra-fast balanced SSFP provides artifact-free images even for targets with severe susceptibility variations, and native high-resolution structural and functional in vivo 1H imaging of the human lung is demonstrated at 1.5 T. Conclusion On clinical whole body MRI systems, the TR of SSFP-based Cartesian imaging can be pushed toward the 1 ms regime. As a result, ultra-fast SSFP protocols might represent a promising new powerful approach for SSFP-based imaging, not only for lung but also in a variety of clinical and scientific applications. Copyright © 2013 Wiley Periodicals, Inc.

References Powered by Scopus

Principles and applications of balanced SSFP techniques

587Citations
N/AReaders
Get full text

Engineering and algorithm design for an image processing API: A technical report on ITK - The Insight Toolkit

549Citations
N/AReaders
Get full text

Steady-state free precession in nuclear magnetic resonance

391Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Detection of small pulmonary nodules with ultrashort echo time sequences in oncology patients by using a PET/MR system

135Citations
N/AReaders
Get full text

Fibrosis imaging: Current concepts and future directions

114Citations
N/AReaders
Get full text

Functional imaging of the lungs with gas agents

101Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Bieri, O. (2013). Ultra-fast steady state free precession and its application to in vivo 1H morphological and functional lung imaging at 1.5 tesla. Magnetic Resonance in Medicine, 70(3), 657–663. https://doi.org/10.1002/mrm.24858

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 33

59%

Researcher 17

30%

Professor / Associate Prof. 4

7%

Lecturer / Post doc 2

4%

Readers' Discipline

Tooltip

Engineering 16

36%

Medicine and Dentistry 15

34%

Physics and Astronomy 11

25%

Neuroscience 2

5%

Save time finding and organizing research with Mendeley

Sign up for free