Purpose: This study aimed to evaluate the 24-month efficacy of viscodilation of Schlemm’s canal and the distal outflow system with iTrack ab-interno canaloplasty in reducing intrao- cular pressure (IOP) and antiglaucoma medication use in patients with primary open-angle glaucoma (POAG). Patients and Methods: This retrospective, comparative, and consecutive case series assessed the 24-month outcomes of iTrack as a standalone procedure (iTrack-alone) or in conjunction with cataract surgery (iTrack+phaco), in cases of mild, moderate or severe POAG. Data were collected at baseline and the 12- and 24-month follow-up visits. Results: The study included 53 patients (60 eyes) with a mean age of 73.6±9 years. For all eyes, a significant reduction in mean IOP was seen at 12 and 24 months, reducing from 20 ±4.9 mmHg at baseline to 13.6±1.9 mmHg and 13.5±2.6 mmHg, respectively (P<0.001). The reduction in medications was also significant, reducing to 1.12±1.09 and 1.7±1.29 medica- tions at 12 months and 24 months, respectively, from a baseline of 2.77±0.91 (P<0.001). Similar results were achieved whether iTrack was performed as a standalone procedure, or in conjunction with cataract surgery. While the iTrack-alone group started with a higher IOP at baseline, both groups experienced similar and stable IOP reduction of more than 30% from baseline. The reduction in medication use was also significant in both groups, decreasing from 3±0.7 for iTrack-alone and 2.5±1.1 for iTrack+phaco at baseline to 2.1±1.3 and 1.3±1.2 at 24 months, respectively (P<0.001). The 24-month efficacy outcomes were similar in cases of mild-moderate versus severe glaucoma. No serious adverse events were recorded. Conclusion: Twenty-four-month follow-up data demonstrate that iTrack ab-interno canalo- plasty can effectively reduce IOP and medication dependence, with a good safety profile. These results also demonstrate that iTrack can be effectively performed as a standalone procedure or in combination with cataract surgery, and in all grades of glaucoma severity.

Cite

CITATION STYLE

APA

Gallardo, M. J. (2021). 24-month efficacy of viscodilation of schlemm’s canal and the distal outflow system with itrack ab-interno canaloplasty for the treatment of primary open-angle glaucoma. Clinical Ophthalmology, 15, 1591–1599. https://doi.org/10.2147/OPTH.S272506

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free