Significance of PQ interval in acquisition of coronary multidetector row computed tomography

5Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Since image quality obtained in the mid-diastolic [or slow filling (SF)] phase is generally superior to end-systolic image in coronary multidetector row computed tomography (MDCT), low heart rate (HR) comprises the most important factor for acquisition of high-quality images. However, despite HR <70 and optimum breath-hold, sometimes high quality images cannot be obtained in SF. We assessed the significance of PQ interval in acquisition of coronary MDCT. Methods and results: Of 541 consecutive patients who underwent coronary MDCT, 7 patients with incomplete breath-hold, 62 HR ≥70, and 70 arrhythmias were excluded. The remaining 402 patients (M: 222, 66 ± 11 years), including 38 with first-degree atrioventricular block (1°AVB, PQ >200 ms) were evaluated. RR and PQ were measured on electrocardiogram and systolic and SF phase with 4-chamber cine cardiac computed tomography. SF significantly (p < 0.0001) correlated with RR (SF = -471 + 0.720RR, r = 0.887) in all subjects. The SF of without 1°AVB (292 ± 97 ms) was significantly (p < 0.0147) longer than that of with 1°AVB (251 ± 121 ms), although RR was not significantly different between the two groups. The SF/RR of without 1°AVB (27.2 ± 6.1%) was also significantly (p < 0.0001) higher than that of with 1°AVB (22.7 ± 8.0%). The coefficient of correlation between (RR - PQ) and SF [r = 0.915, p < 0.0001, SF = -362 + 0.742(RR - PQ)] was significantly (p < 0.034) higher than that of correlation between RR and SF in all subjects. The SF of rank A image quality was significantly longer than that of rank B (p < 0.0001) or rank C (p = 0.0042). In critical HR (60-69 bpm), the optimum phase was ES in 7/139 patients without 1°AVB, and SF in 3/13 patients with 1°AVB (χ2, p < 0.0416). Conclusion: Since SF depends on (RR - PQ), if PQ is long in critical HR, it might be difficult to reconstruct high quality images in the SF phase. © 2009 Japanese College of Cardiology.

Cite

CITATION STYLE

APA

Sano, T., Kondo, T., Matsutani, H., Morita, H., Arai, T., Sekine, T., … Narula, J. (2009). Significance of PQ interval in acquisition of coronary multidetector row computed tomography. Journal of Cardiology, 54(3), 441–451. https://doi.org/10.1016/j.jjcc.2009.07.004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free