We have developed lumped element kinetic inductance detectors (LEKIDs) that are sensitive in the frequency band from 80 to 120 GHz. In this work, we take advantage of the so-called proximity effect to reduce the superconducting gap of aluminium (Al), otherwise strongly suppressing the LEKID response for frequencies smaller than 100 GHz. We designed, produced, and optically tested various fully multiplexed arrays based on multi-layer combinations of Al and titanium (Ti). Their sensitivities were measured using a dedicated closed-circle 100 mK dilution cryostat and a sky simulator, which allowed us to reproduce realistic observation conditions. The spectral response was characterised with a Martin-Puplett interferometer up to THz frequencies and had a resolution of 3 GHz. We demonstrate that Ti-Al LEKID can reach an optical sensitivity of about 1.4 × 10 -17 W/Hz 0.5 (best pixel), or 2.2 × 10 -17 W/Hz 0.5 when averaged over the whole array. The optical background was set to roughly 0.4 pW per pixel, which is typical for future space observatories in this particular band. The performance is close to a sensitivity of twice the CMB photon noise limit at 100 GHz, which drove the design of the Planck HFI instrument. This figure remains the baseline for the next generation of millimetre-wave space satellites.
CITATION STYLE
Catalano, A., Goupy, J., Le Sueur, H., Benoit, A., Bourrion, O., Calvo, M., … Monfardini, A. (2015). Bi-layer kinetic inductance detectors for space observations between 80-120 GHz. Astronomy and Astrophysics, 580. https://doi.org/10.1051/0004-6361/201526206
Mendeley helps you to discover research relevant for your work.