Abstract

A novel procedure for a robust assessment of cavity deformation in Fabry–Pérot (FP) refractometers is presented. It is based on scrutinizing the difference between two pressures: one assessed by the uncharacterized refractometer and the other provided by an external pressure reference system, at a series of set pressures for two gases with dissimilar refractivity (here, He and N2). By fitting linear functions to these responses and extracting their slopes, it is possible to construct two physical entities of importance: one representing the cavity deformation and the other comprising a combination of the systematic errors of a multitude of physical entities, viz., those of the assessed temperature, the assessed or estimated penetration depth of the mirror, the molar polarizabilities, and the set pressure. This provides a robust assessment of cavity deformation with small amounts of uncertainties. A thorough mathematical description of the procedure is presented that serves as a basis for the evaluation of the basic properties and features of the procedure. The analysis indicates that the cavity deformation assessments are independent of systematic errors in both the reference pressure and the assessment of gas temperature and when the gas modulation refractometry methodology is used that they are insensitive to gas leakages and outgassing into the system. It also shows that when a high-precision (sub-ppm) refractometer is characterized according to the procedure, when high purity gases are used, the uncertainty in the deformation contributes to the uncertainty in the assessment of pressure of N2 with solely a fraction (13%) of the uncertainty of its molar polarizability, presently to a level of a few ppm. This implies, in practice, that cavity deformation is no longer a limiting factor in FP-based refractometer assessments of pressure of N2.

References Powered by Scopus

Perspectives for a new realization of the pascal by optical methods

108Citations
N/AReaders
Get full text

Refractivity virial coefficients of gaseous CH<inf>4</inf>, C <inf>2</inf>H<inf>4</inf>, C<inf>2</inf>H<inf>6</inf>, CO<inf>2</inf>, SF <inf>6</inf>, H<inf>2</inf>, N<inf>2</inf>, He, and Ar

88Citations
N/AReaders
Get full text

Performance of a dual Fabry-Perot cavity refractometer

85Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Optical realization of the pascal—Characterization of two gas modulated refractometers

27Citations
N/AReaders
Get full text

Perspective on the Refractive-Index Gas Metrology Data Landscape

26Citations
N/AReaders
Get full text

Characterization of a vacuum pressure standard based on optical refractometry using nitrogen developed at NIM

21Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Zakrisson, J., Silander, I., Forssén, C., Zelan, M., & Axner, O. (2020). Procedure for robust assessment of cavity deformation in Fabry–Pérot based refractometers. Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena, 38(5). https://doi.org/10.1116/6.0000375

Readers' Seniority

Tooltip

Researcher 4

57%

Professor / Associate Prof. 2

29%

PhD / Post grad / Masters / Doc 1

14%

Readers' Discipline

Tooltip

Physics and Astronomy 2

50%

Neuroscience 1

25%

Engineering 1

25%

Save time finding and organizing research with Mendeley

Sign up for free