A Possible 1.8 K Refrigeration Cycle for the Large Hadron Collider

  • Millet F
  • Roussel P
  • Tavian L
  • et al.
N/ACitations
Citations of this article
1Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The Large Hadron Collider (LHC) under construction at the European Laboratory for Particle Physics, CERN, will make use of superconducting magnets operating below 2.0 K. This requires, for each of the eight future cryogenic installations, an isothermal cooling capacity of up to 2.4 kW obtained by vaporisation of helium II at 1.6 kPa and 1.8 K. The process design for this cooling duty has to satisfY several demands. It has to be adapted to four already existing as well as to four new refrigerators. It must cover a dynamic range of one to three, and it must allow continuous pump-down from 4.5 K to 1.8 K. A possible solution, as presented in this paper, includes a combination of cold centrifugal and warm volumetric compressors. It is characterised by a low thermal load on the refrigerator, and a large range of adaptability to different operation modes. The expected power factor for 1.8 K cooling is given, and the proposed control strategy is explained.

Cite

CITATION STYLE

APA

Millet, F., Roussel, P., Tavian, L., & Wagner, U. (1998). A Possible 1.8 K Refrigeration Cycle for the Large Hadron Collider. In Advances in Cryogenic Engineering (pp. 387–393). Springer US. https://doi.org/10.1007/978-1-4757-9047-4_46