Linear and angular measurements of computer-generated models: Are they accurate, valid, and reliable?

39Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

Introduction: Traditional advanced imaging modalities such as CT and MRI are limited in their ability to perform accurate linear distance and angular measurements regardless of anatomical orientation. The construction of 3D models has been used to perform anthropometric analyses as well as in the reconstruction of rapid prototypes. We hypothesized that such measurements would be precise to within 2 mm or 2° of measurements performed with a coordinate measurement machine (CMM). We also hypothesized that there would be a high degree of interobserver reliability with these measurements. Materials and Methods: Multiple aluminum screws were implanted in various positions in three foam pelvises which were subsequently scanned by CT and rendered as 3D models using a commercially available software package (Mimics). Linear and angular measurements were performed using a CMM machine, the software package, and a dial caliper or goniometer. The deviation of the measurements from the CMM data was compared using ANOVA. The interobserver reliability of both the manual and computer-generated measurements was calculated. Results: The mean difference between the CMM distances and those measured manually and with the software was 2.12 ± 1.20 mm and 1.57 ± 1.05 mm, respectively. The mean difference between the CMM angular measurements and the angular measurements performed manually and with the software was 4.07 ± 4.70° and 1.62 ± 1.32°, respectively. In all cases, the manual measurements were significantly less accurate (p < 0.0001) and there was a high degree of interobserver reliability. Conclusions: Computer-generated measurements taken from three-dimensionally reconstructed models are more accurate than manual measurements and are within 2 mm and 2° of measurements performed with a CMM. These measurements have high interobserver reliability. © 2007 Informa UK Ltd.

References Powered by Scopus

Etiology of osteoarthritis of the hip

719Citations
N/AReaders
Get full text

Volume determinations using computed tomography

321Citations
N/AReaders
Get full text

Anteroposterior pelvic radiographs to assess acetabular retroversion: High validity of the "cross-over-sign"

311Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Investigation of intracranial aneurysm hemodynamics following flow diverter stent treatment

70Citations
N/AReaders
Get full text

Femoroacetabular impingement: Current concepts in diagnosis and treatment

69Citations
N/AReaders
Get full text

Do small changes in rotation affect measurements of lower extremity limb alignment?

61Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Jamali, A. A., Deuel, C., Perreira, A., Salgado, C. J., Hunter, J. C., & Strong, E. B. (2007). Linear and angular measurements of computer-generated models: Are they accurate, valid, and reliable? Computer Aided Surgery, 12(5), 278–285. https://doi.org/10.1080/10929080701680265

Readers over time

‘11‘13‘14‘15‘16‘18‘19‘20‘21‘22‘23‘2500.751.52.253

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

62%

Professor / Associate Prof. 3

23%

Lecturer / Post doc 1

8%

Researcher 1

8%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

46%

Engineering 3

23%

Veterinary Science and Veterinary Medic... 3

23%

Social Sciences 1

8%

Save time finding and organizing research with Mendeley

Sign up for free
0