Abstract

Monitoring uterine contractions is essential during pregnancy and labor to obtain information on time-to-delivery and maternal and fetal wellbeing Intrauterine pressure (IUP) is considered the “gold standard” to monitor uterine activity, though it requires membrane rupture and is highly invasive. Considering that uterine mechanical activity is a direct consequence of uterine myoelectrical activity, IUP signal can be non-invasively estimated from abdominal electrohysterogram (EHG) recordings. Previous works have reported EHG-based IUP estimates with linear parameters as root-mean-square or Teager energy. Due to non-linear nature of biological processes, the aim of this study was to test the performance of different non-linear EHG parameters to estimate IUP signal. Simultaneous EHG and IUP recordings were conducted in 17 women during labour. Teager energy (TE), Sample entropy (SampEn), Spectral entropy (SpEn), Lempel-Ziv (LZ), and Poincaré parameters: SD1, SD2, SDRR and SD1/SD2 were computed from the EHG. Different window lengths for computation and for a smoothing moving average filter were tested. Monovariable linear regression models were used to obtain IUP estimates. The best results were obtained with TE and SD1, both computed and filtered with windows of 5 s and 20 s, respectively. In the latter case, the RMSerror was 12.25 ± 4.03 mmHg, which points that non-linear EHG parameters can provide relevant information for non-invasive uterine activity monitoring.

References Powered by Scopus

Physiological time-series analysis using approximate and sample entropy

6646Citations
N/AReaders
Get full text

Interpretation of the Lempel-Ziv complexity measure in the context of biomedical signal analysis

332Citations
N/AReaders
Get full text

Monitoring uterine activity during labor: A comparison of 3 methods

168Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Automatic detection and characterization of uterine contraction using Electrohysterography

2Citations
N/AReaders
Get full text

Labour diagnostics using the intrauterine pressure through sound waves emitted by a smartphone

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Albaladejo-Belmonte, M., Prats-Boluda, G., Ye-Lin, Y., Benalcazar-Parra, C., Lopez, Á., Perales, A., & Garcia-Casado, J. (2020). Non-invasive Intrauterine Pressure Estimation Based on Nonlinear Parameters Computed from the Electrohysterogram. In IFMBE Proceedings (Vol. 76, pp. 117–124). Springer. https://doi.org/10.1007/978-3-030-31635-8_14

Readers' Seniority

Tooltip

Professor / Associate Prof. 2

50%

Lecturer / Post doc 1

25%

PhD / Post grad / Masters / Doc 1

25%

Readers' Discipline

Tooltip

Medicine and Dentistry 1

33%

Engineering 1

33%

Neuroscience 1

33%

Save time finding and organizing research with Mendeley

Sign up for free