Optical coherence tomography of de novo lesions and in-stent restenosis in coronary saphenous vein grafts (octopus study)

5Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

Abstract

Background: The OCTOPUS registry prospectively evaluates the procedural and long-term outcomes of saphenous vein graft (SVG) PCI. The current study assessed the morphology of de novo lesions and in-stent restenosis (ISR) in patients undergoing PCI of SVG. Methods and Results: Optical coherence tomography (OCT) of SVG lesions in consecutive patients presenting with stable CAD and ACS was carried out. Thirty-nine patients (32 de novo and 10 ISR lesions) were included in the registry. ISR occurred in 5 BMS and 5 DES. There were no differences in the presence of plaque rupture and thrombus between de novo lesions and ISR. Lipid-rich tissue was identified in both de novo lesions and in ISR (75% vs. 50%, P=0.071) with a higher prevalence in BMS than in DES (23% vs. 7.5%; P=0.048). Calcific de novo lesions were detected in older grafts as compared with non-calcific atheromas (159±57 vs. 90±62 months after CABG, P=0.001). Heterogeneous neointima was found only in ISR (70% vs. 0, P<0.001) and was observed with similar frequency in both BMS and DES (24% vs. 30%, P=0.657). ISR was detected earlier in DES than BMS (median, 50 months; IQR, 18–96 months vs. 27 months; IQR, 13–29 months, P<0.001). Conclusions: OCT-based characteristics of de novo and ISR lesions in SVG were similar except for heterogeneous tissue, which was observed only in ISR.

References Powered by Scopus

2014 ESC/EACTS Guidelines on myocardial revascularization: The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)Developed with the special contribution of the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

4274Citations
N/AReaders
Get full text

Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: A report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation

1607Citations
N/AReaders
Get full text

Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years

1219Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Multimodality intravascular imaging of bioresorbable vascular scaffolds implanted in vein grafts

2Citations
N/AReaders
Get full text

Saphenous graft atherosclerosis as assessed by optical coherence tomography data for stenotic and non-stenotic lesions from the OCTOPUS registry

2Citations
N/AReaders
Get full text

Prediction models for different plaque morphology in non-significantly stenosed regions of saphenous vein grafts assessed with optical coherence tomography

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Roleder, T., Pociask, E., Wańha, W., Dobrolińska, M., Gąsior, P., Smolka, G., … Wojakowski, W. (2016). Optical coherence tomography of de novo lesions and in-stent restenosis in coronary saphenous vein grafts (octopus study). Circulation Journal, 80(8), 1804–1811. https://doi.org/10.1253/circj.CJ-16-0332

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

55%

Professor / Associate Prof. 3

27%

Lecturer / Post doc 1

9%

Researcher 1

9%

Readers' Discipline

Tooltip

Medicine and Dentistry 9

75%

Nursing and Health Professions 1

8%

Computer Science 1

8%

Sports and Recreations 1

8%

Save time finding and organizing research with Mendeley

Sign up for free