Comparison of blood pressure measurements in the upper and lower extremities versus arterial blood pressure readings in children under general anesthesia

6Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare invasive blood pressure (IBP) readings obtained from an arterial cannula with non-invasive blood pressure (NIBP) measurements from oscillometric cuffs on the upper and lower extremities of infants and children under general anesthesia. Patients and methods: Patients under 10 years of age were enrolled in our study if they were to receive general anesthesia with planned placement of a radial arterial cannula. At 5 mins intervals, IBP was measured using a fluid-coupled pressure transducer and NIBP was measured with two oscillometers with appropriately sized cuffs placed on the upper arm and lower leg, for 10 readings per patient. Results: The study enrolled 18 boys and 12 girls, ranging in age from 0 to 8 years. Across 300 data points, the absolute difference between the arm and invasive mean arterial pressure (MAP) measurements was 7±7 mmHg (range: 0-52 mmHg). The absolute difference between the leg and invasive MAP measurements was 8±8 mmHg (range: 0-52 mmHg). Although both non-invasive measurement sites demonstrated frequent deviation from invasive measurement, large deviations were more common when BP was measured at the leg (81 of 298 observations (27%) deviating by >10 mmHg) compared to the arm (60 of 300 observations (20%) deviating by >10 mmHg). Conclusion: The frequency of clinically significant NIBP deviation in children under general anesthesia supports the importance of IBP monitoring when hemodynamic fluctuations are likely and would be particularly detrimental. NIBP measured at the lower leg is more likely to result in clinically significant deviation from invasively measured MAP than NIBP values obtained from an upper arm.

Cite

CITATION STYLE

APA

Hayes, S., Miller, R., Patel, A., Tumin, D., Walia, H., Hakim, M., … Tobias, J. D. (2019). Comparison of blood pressure measurements in the upper and lower extremities versus arterial blood pressure readings in children under general anesthesia. Medical Devices: Evidence and Research, 12, 297–303. https://doi.org/10.2147/MDER.S209629

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free