An experimental study on lung deposition of inhaled 2 μm particles in relation to lung characteristics and deposition models

2Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The understanding of inhaled particle respiratory tract deposition is a key link to understand the health effects of particles or the efficiency for medical drug delivery via the lung. However, there are few experimental data on particle respiratory tract deposition, and the existing data deviates considerably when comparing results for particles > 1 μm. Methods: We designed an experimental set-up to measure deposition in the respiratory tract for particles > 1 μm, more specifically 2.3 μm, with careful consideration to minimise foreseen errors. We measured the deposition in seventeen healthy adults (21–68 years). The measurements were performed at tidal breathing, during three consecutive 5-minute periods while logging breathing patterns. Pulmonary function tests were performed, including the new airspace dimension assessment (AiDA) method measuring distal lung airspace radius (r AiDA). The lung characteristics and breathing variables were used in statistical models to investigate to what extent they can explain individual variations in measured deposited particle fraction. The measured particle deposition was compared to values predicted with whole lung models. Model calculations were made for each subject using measured variables as input (e.g., breathing pattern and functional residual capacity). Results: The measured fractional deposition for 2.3 μm particles was 0.60 ± 0.14, which is significantly higher than predicted by any of the models tested, ranging from 0.37 ± 0.08 to 0.53 ± 0.09. The multiple-path particle dosimetry (MPPD) model most closely predicted the measured deposition when using the new PNNL lung model. The individual variability in measured particle deposition was best explained by breathing pattern and distal airspace radius (r AiDA) at half inflation from AiDA. All models underestimated inter-subject variability even though the individual breathing pattern and functional residual capacity for each participant was used in the model. Conclusions: Whole lung models need to be tuned and improved to predict the respiratory tract particle deposition of micron-sized particles, and to capture individual variations – a variation that is known to be higher for aged and diseased lungs. Further, the results support the hypothesis that the AiDA method measures dimensions in the peripheral lung and that r AiDA, as measured by the AiDA, can be used to better understand the individual variation in the dose to healthy and diseased lungs.

Cite

CITATION STYLE

APA

Rissler, J., Sjögren, M. P., Linell, J., Hurtig, A. L., Wollmer, P., & Löndahl, J. (2023). An experimental study on lung deposition of inhaled 2 μm particles in relation to lung characteristics and deposition models. Particle and Fibre Toxicology, 20(1). https://doi.org/10.1186/s12989-023-00551-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free