Abstract

In this work, a slightly modified 100g R134a domestic refrigerator was retrofitted with limited mass charge (30g) of R600a and LPG refrigerants and tested in different ambient temperature conditions (19, 21, 23 and 25 °C). The test rig was fitted with appropriate instrumentation for experimentation. Performance characteristics investigated with the test rig at steady state include evaporator air temperature, discharge temperature and power consumption. Results showed that the retrofitted hydrocarbon refrigerants in the system at the ambient conditions gave power consumption, discharge temperature, condensing pressure lower by 15 - 45 %, 16 - 30 % and 25 - 62 % than R134a refrigerant. In addition, the cabinet temperature of the system with the hydrocarbon refrigerants were higher than R134a by 10 - 60 %. In conclusion, the investigated energetic characteristics of the system improved with reducing ambient temperature and all conditions with infused hydrocarbon refrigerants attained cabinet temperatures lower than -3 °C in accordance to ISO 8187 recommendation for domestic refrigerators.

Author supplied keywords

Cite

CITATION STYLE

APA

Olatunji, O. R., Ohunakin, O. S., & Adelekan, D. S. (2019). Performance of a Limited Charge of R600a and LPG Refrigerants in a Domestic Refrigerator Using R134a Refrigerant in Different Ambient Conditions. In Journal of Physics: Conference Series (Vol. 1378). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/1378/2/022101

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free