Measurement uncertainty of chromogenic LAL assays: Reaction time and proportion of endotoxin and LAL reagent affect release of p-nitroaniline

14Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Limulus Amebocyte Lysate (LAL) assays are widely used for detection and quantification of bacterial endotoxins in pharmaceuticals and medical devices. However, there are only a few studies on the measurement uncertainty of LAL assays. The aim of this work was to identify and quantify the main sources of measurement uncertainty for end point and kinetic-chromogenic LAL assays. Response surface methodology was used to study how the release of p-nitroaniline (pNA) is affected by reaction time and proportion of endotoxin and LAL reagent in end point and kinetic-chromogenic LAL assays, respectively. Increased release of pNA was observed when reaction time was increased. In addition, if different volumes of sample (or endotoxin standard) and LAL reagent are used, the pNA release rate will be affected. These results may be due to the increased interaction between the bacterial endotoxin and LAL-activated enzyme. Final measurement uncertainties (95% confidence interval) were 90-120% and 90-127% of bacterial endotoxin content for end point and kinetic-chromogenic assays, respectively. These values are reasonable for the scope of the method and allow the application of these measurement uncertainties in routine analysis of pharmaceuticals and medical devices.

References Powered by Scopus

Clottable protein in Limulus; its localization and kinetics of its coagulation by endotoxin.

487Citations
N/AReaders
Get full text

Chemical structure of escherichia coli lipid A

71Citations
N/AReaders
Get full text

Quantifying uncertainty in qualitative analysis

55Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Design of experiments (DoE) applied to pharmaceutical and analytical quality by design (QbD)

262Citations
N/AReaders
Get full text

Current technologies to endotoxin detection and removal for biopharmaceutical purification

81Citations
N/AReaders
Get full text

Recent advances in biosensor based diagnosis of urinary tract infection

58Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ostronoff, C. S., & Lourenҫo, F. R. (2015). Measurement uncertainty of chromogenic LAL assays: Reaction time and proportion of endotoxin and LAL reagent affect release of p-nitroaniline. Journal of AOAC International, 98(1), 51–55. https://doi.org/10.5740/jaoacint.14-118

Readers over time

‘15‘16‘17‘18‘19‘20‘21‘22‘23‘2400.751.52.253

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

80%

Professor / Associate Prof. 1

20%

Readers' Discipline

Tooltip

Pharmacology, Toxicology and Pharmaceut... 2

40%

Engineering 1

20%

Agricultural and Biological Sciences 1

20%

Biochemistry, Genetics and Molecular Bi... 1

20%

Save time finding and organizing research with Mendeley

Sign up for free
0