Technical note: Impact of dose voxel kernel (DVK) values on dosimetry estimates in 177Lu and 90Y radiopharmaceutical therapy (RPT) applications

3Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Radiopharmaceutical therapy (RPT) is an increasingly adopted modality for treating cancer. There is evidence that the optimization of the treatment based on dosimetry can improve outcomes. However, standardization of the clinical dosimetry workflow still represents a major effort. Among the many sources of variability, the impact of using different Dose Voxel Kernels (DVKs) to generate absorbed dose (AD) maps by convolution with the time-integrated activity (TIA) distribution has not been systematically investigated. Purpose: This study aims to compare DVKs and assess the differences in the ADs when convolving the same TIA map with different DVKs. Methods: DVKs of 3 × 3 × 3 mm3 sampling—nine for 177Lu, nine for 90Y—were selected from those most used in commercial/free software or presented in prior publications. For each voxel within a 11 × 11 × 11 matrix, the coefficient of variation (CoV) and the percentage difference between maximum and minimum values (% maximum difference) were calculated. The total absorbed dose per decay (SUM), calculated as the sum of all the voxel values in each kernel, was also compared. Publicly available quantitative SPECT images for two patients treated with 177Lu-DOTATATE and PET images for two patients treated with 90Y-microspheres were used, including organs at risk (177Lu: kidneys; 90Y: liver and healthy liver) and tumors’ segmentations. For each patient, the mean AD to the volumes of interest (VOIs) was calculated using the different DVKs, the same TIA map and the same software tool for dose convolution, thereby focusing on the DVK impact. For each VOI, the % maximum difference of the mean AD between maximum and minimum values was computed. Results: The CoV (% maximum difference) in voxels of normalized coordinates [0,0,0], [0,1,0], and [0,1,1] were 5%(21%), 9%(35%), and 10%(46%) for the 177Lu DVKs. For the case of 90Y, these values were 2%(9%), 4%(14%), and 4%(16%). The CoV (% maximum difference) for SUM was 9%(33%) for 177Lu, and 4%(15%) for 90Y. The variability of the mean tumor and organ AD was up to 19% and 15% in 177Lu-DOTATATE and 90Y-microspheres patients, respectively. Conclusions: This study showed a considerable AD variability due exclusively to the use of different DVKs. A concerted effort by the scientific community would contribute to decrease these discrepancies, strengthening the consistency of AD calculation in RPT.

References Powered by Scopus

Personalised versus standard dosimetry approach of selective internal radiation therapy in patients with locally advanced hepatocellular carcinoma (DOSISPHERE-01): a randomised, multicentre, open-label phase 2 trial

405Citations
N/AReaders
Get full text

Availability of nuclear decay data in electronic form, including beta spectra not previously published

120Citations
N/AReaders
Get full text

Reliability of usual assumptions in the calculation of β and ν spectra

104Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Methodology for comparing absorbed dose rate calculation algorithms in molecular radiotherapy dosimetry

0Citations
N/AReaders
Get full text

Validation of Particle and Heavy Ion Transport Code System (PHITS) in generating dose-voxel kernels for internal dosimetry calculations

0Citations
N/AReaders
Get full text

A novel database of <sup>90</sup>Y voxel S-Values including Internal Bremsstrahlung and an analytical model extending the calculation to any voxel size

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Danieli, R., Pistone, D., Tranel, J., Botta, F., Uribe-Munoz, C., Raspanti, D., … Cremonesi, M. (2024). Technical note: Impact of dose voxel kernel (DVK) values on dosimetry estimates in 177Lu and 90Y radiopharmaceutical therapy (RPT) applications. Medical Physics, 51(1), 522–532. https://doi.org/10.1002/mp.16729

Readers over time

‘23‘2402468

Readers' Seniority

Tooltip

Researcher 4

50%

PhD / Post grad / Masters / Doc 3

38%

Professor / Associate Prof. 1

13%

Readers' Discipline

Tooltip

Physics and Astronomy 7

88%

Chemistry 1

13%

Save time finding and organizing research with Mendeley

Sign up for free
0