Lung Ultrasound Score in COVID-19 Patients Correlates with PO2/FiO2, Intubation Rates, and Mortality

2Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

Introduction: The point-of-care lung ultrasound (LUS) score has been used in coronavirus 2019 (COVID-19) patients for diagnosis and risk stratification, due to excellent sensitivity and infection control concerns. We studied the ratio of partial pressure of oxygen in arterial blood to the fraction of inspiratory oxygen concentration (PO2/FiO2), intubation rates, and mortality correlation to the LUS score. Methods: We conducted a systematic review using PRISMA guidelines. Included were articles published from December 1, 2019–November 30, 2021 using LUS in adult COVID-19 patients in the intensive care unit or the emergency department. Excluded were studies on animals and on pediatric and pregnant patients. We assessed bias using QUADAS-2. Outcomes were LUS score and correlation to PO2/FiO2, intubation, and mortality rates. Random effects model pooled the meta-analysis results. Results: We reviewed 27 of 5,267 studies identified. Of the 27 studies, seven were included in the intubation outcome, six in the correlation to PO2/FiO2 outcome, and six in the mortality outcome. Heterogeneity was found in ultrasound protocols and outcomes. In the pooled results of 267 patients, LUS score was found to have a strong negative correlation to PO2/FiO2 with a correlation coefficient of −0.69 (95% confidence interval [CI] −0.75, −0.62). In pooled results, 273 intubated patients had a mean LUS score that was 6.95 points higher (95% CI 4.58–9.31) than that of 379 non-intubated patients. In the mortality outcome, 385 survivors had a mean LUS score that was 4.61 points lower (95% CI 3.64–5.58) than that of 181 non-survivors. There was significant heterogeneity between the studies as measured by the I2 and Cochran Q test. Conclusion: A higher LUS score was strongly correlated with a decreasing PO2/FiO2 in COVID-19 pneumonia patients. The LUS score was significantly higher in intubated vs non-intubated patients with COVID-19. The LUS score was significantly lower in critically ill patients with COVID-19 pneumonia that survive.

Cite

CITATION STYLE

APA

Lai, S. Y., Schafer, J. M., Meinke, M., Beals, T., Doff, M., Grossestreuer, A., & Hoffmann, B. (2024). Lung Ultrasound Score in COVID-19 Patients Correlates with PO2/FiO2, Intubation Rates, and Mortality. Western Journal of Emergency Medicine, 25(1), 28–39. https://doi.org/10.5811/westjem.59975

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free