Structural pounding between adjoining multistory buildings with different total heights and different story levels has been repeatedly identified as a frequent cause of severe damage during seismic excitations. This phenomenon is very intense when upper floor slabs of short buildings hit the columns of taller and more flexible structures within their deformable length. On the other hand, it is well accepted that infill masonry panels strongly affect the seismic response and overall behavior of multistory reinforced concrete (RC) frames and especially in the common case of an open first story (pilotis). Thereupon, the interaction between a multistory frame with an open first floor and shorter and stiffer adjacent buildings was studied and the influence of the open first story on pounding investigated with inelastic dynamic step-by-step analyses. The results of the pounding cases of an 8-story RC frame with a single story and 4-story buildings were examined. Three cases of short structures were considered as follows: a frame structure, a stiff structure and a very stiff non-self-vibrating one. All studied interaction cases included type A (floor-to-floor) pounding cases and type B (floor-to-column) pounding cases. This study focused on the influence of an open first story (pilotis) on the pounding phenomenon. Therefore, all examined two-building poundings were studied considering two cases: the first case involving a fully infilled 8-story frame and second case involving an infilled 8-story structure with an open first story (pilotis). Moreover, as expected due to the asymmetry of the examined two-structured pounding pairs, the directions (plus and minus) of the seismic excitation proved to be important for the evaluation of the developing capacity demands. In the present study for the first time, it is stressed that pounding cases between structures with different geometries (asymmetric) have to be examined in both directions (plus and minus) of each seismic excitation. From the results, it can be deduced that the developing shear forces on the columns that suffer a hit in the case of type B pounding exceed the shear strength of the column even if detailing for critical regions according to Eurocode 8 is applied. Further, it is inferred that pilotis configuration increases the developing pounding forces and consequently increases the capacity demands mainly in terms of the ductility of the column that suffers the hit.
CITATION STYLE
Manoukas, G. E., & Karayannis, C. G. (2023). Seismic Interaction between Multistory Pilotis RC Frames and Shorter Structures with Different Story Levels—Floor-to-Column Pounding. CivilEng, 4(2), 618–637. https://doi.org/10.3390/civileng4020036
Mendeley helps you to discover research relevant for your work.