Clinical evaluation of keratometry and computerised videokeratography: Intraobserver and interobserver variability on normal and astigmatic corneas

11Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

Aims. To evaluate intra- and interobserver variability in measurements on normal and astigmatic corneas with keratometry and computerised videokeratography. Methods. Keratometric readings with the 10 SL/O Zeiss keratometer and topographic maps with the TMS-1 were obtained by two independent examiners on 32 normal and 33 postkeratoplasty corneas. Inter- and intraobserver coefficients of variability (COR) for measurements of steep and flat meridian power and location, in addition to the magnitude of astigmatism, were assessed. Results. Compared with TMS-1, the 10 SL/O keratometer showed a superior repeatability in measuring normal corneas (intraobserver COR for keratometry and TMS-1 respectively: 0.22 and 0.30 D for steep meridian power; 0.18 and 0.44 D for flat meridian power; 0.26 and 0.40 D for astigmatism; 5°and 26°for steep meridian location; 5°and 13°for flat meridian location). Astigmatism intraobserver COR (0.20 D and 0.26 D for the two observers) and interobserver COR (0.28 D) of the keratometer for normal corneas was very good and not affected by observers' experience. Repeatability of the TMS-1 on normal corneas was found to be: (a) observer related, and (b) astigmatism related. A novice observer showed a much greater COR (1.62 D for astigmatism, 30°for flat meridian location) compared with the experienced examiner (0.40 D for astigmatism, 13°for flat meridian location). Higher deviation scores were observed for corneas with higher astigmatism. For the postkeratoplasty corneas, again the keratometer achieved superior reproducibility (astigmatism interobserver COR 1.12 D for keratometry, 4.06 D for TMS-1; steep meridian location interobserver COR 10°for keratometry, 34°for TMS-1). Conclusion. Keratometric readings are more reproducible than topographic data both for normal and postkeratoplasty corneas. The two instruments should not be used interchangeably especially on highly astigmatic corneas. For the TMS-1, users with the same level of experience should be employed in clinical or experimental studies.

Cite

CITATION STYLE

APA

Karabatsas, C. H., Cook, S. D., Papaefthymiou, J., Turner, P., & Sparrow, J. M. (1998). Clinical evaluation of keratometry and computerised videokeratography: Intraobserver and interobserver variability on normal and astigmatic corneas. British Journal of Ophthalmology, 82(6), 637–642. https://doi.org/10.1136/bjo.82.6.637

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free