Diagnostic accuracy of a urine lipoarabinomannan strip-test for TB detection in HIV-infected hospitalised patients

120Citations
Citations of this article
198Readers
Mendeley users who have this article in their library.

Abstract

Lack of point-of-care tests for tuberculosis (TB) result in diagnostic delay, and increased mortality and healthcare-related costs. The urine DetermineTM TB-LAM point-of-care strip-test was evaluated in 335 prospectivelyrecruited hospitalised patients with suspected TB-HIV co-infection (group 1) and from 88 HIVinfected hospitalised patients with non-TB diagnoses (group 2). Cut-off point-specific analyses were performed using: 1) a microbiological reference standard (culture positive versus negative); and 2) a composite reference standard (exclusion of patients with clinical-TB from the culturenegative group). Using the microbiological reference and the manufacturer-recommended grade-1 cut-off point, LAM sensitivity and specificity was 66% (95% CI 57-74%). By contrast, using the composite reference sensitivity was 60% (95% CI 53-67%) and specificity improved to 96% (95% CI 89-100%) (p50.001). The same pattern was seen when the grade-2 cut-off point was used (specificity 75% versus 96%; p=0.01). In group two patients specificity was poor using the grade-1 cut-off point, but improved significantly when the grade-2 cut-off point was used (90% versus 99%; p=0.009). The grade-2 cut-off point also offered superior inter-reader reliability (p=0.002). Sensitivity was highest in those with a CD4 <200 cells per mL. LAM combined with smear-microscopy was able to rule-in TB in 71% of Mycobacterium tuberculosis culture-positive patients. This preliminary study indicates that the LAM strip-test may be a potentially useful rapid rule-in test for TB in hospitalised patients with advanced immunosuppression. The grade 2, but not the manufacturer-recommended grade 1 cut-off point, offered superior rule-in utility and inter-reader reliability. Larger studies to evaluate cut-off points and diagnostic accuracy are urgently required. Copyright © 2012 ERS.

Cite

CITATION STYLE

APA

Peter, J. G., Theron, G., Van Zyl-Smit, R., Haripersad, A., Mottay, L., Kraus, S., … Dheda, K. (2012). Diagnostic accuracy of a urine lipoarabinomannan strip-test for TB detection in HIV-infected hospitalised patients. European Respiratory Journal, 40(5), 1211–1220. https://doi.org/10.1183/09031936.00201711

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free