Comparison of radiation exposure and clinical outcomes between transradial and transfemoral diagnostic cerebral approaches: A retrospective study

4Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Objective To identify and compare patient and procedural variables that are associated with a high radiation dose exposure and worse clinical outcomes between transradial arterial (TRA) and transfemoral arterial (TFA) approaches. Design This was a retrospective analysis. Setting A community hospital during the initial phase of adopting a TRA-first approach. Participants A resultant 215 subjects who only underwent diagnostic cerebral angiograms (DCA) after excluding all therapeutic procedures and patients under 18 years. Interventions Only DCA from 1 May 2018 to 31 January 2021. Main outcome measures We compared radiation exposure parameters (total fluoroscopy time (FT), total radiation dose (TD) and dose area product (DAP), number of vessels injected and Patient-Reported Global Health Physical and Mental Outcome Scores (PROGHS) at 30 days postprocedure between groups. Results FT was significantly greater in TRA compared with TFA (p<0.001). In addition, TRA had a significantly higher TD (p=0.002) and DAP (p=0.005) when compared with TFA. Analysis of only 6-vessel DCAs also showed that TRA had a significantly higher FT, DAP and TD in comparison to TFA. Despite observing a longer FT in TRA, results showed fewer vessels injected and a notably lower success rate in acquiring a 6-vessel DCA using the TRA. Further analysis of the effect of vessel number on FT using general linear models showed that with every increase of one vessel, the FT increases by 2.2 min for TRA (p<0.001; 95% CI 1.03 to 3.36) and by 1.3 min for TFA (p<0.001; 95% CI 0.72 to 1.83). There was no significant difference between groups in PROGHS mental and physical t-scores at 30 days postprocedure, even though our cohort showed a significantly greater percentage of TRA procedures done in the outpatient setting. Conclusions Adopting a TRA first approach for DCAs may be initially associated with a higher radiation dose for the patient. Better strategies and devices are needed to mitigate this effect.

Cite

CITATION STYLE

APA

Amankwah, C., Lombardo, L., Rutledge, J., Sattar, A., Chancellor, B., & Altschul, D. (2022). Comparison of radiation exposure and clinical outcomes between transradial and transfemoral diagnostic cerebral approaches: A retrospective study. BMJ Surgery, Interventions, and Health Technologies, 4(1). https://doi.org/10.1136/bmjsit-2021-000110

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free