External quality assessment (EQA) of Neisseria gonorrhoeae antimicrobial susceptibility testing in primary laboratories in Germany

1Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Worldwide, an increase in antimicrobial resistance (AMR) of Neisseria gonorrhoeae has been observed. Until now, no protocol for an external quality assessment (EQA) has been available for Germany. The German gonococcal resistance network (GORENET) performed an EQA of primary laboratories in Germany in order to assess quality of antibiotic susceptibility testing, to gain information about laboratory procedures and to assess the impact of these procedures on test results. Methods: Laboratories assessed drug susceptibility to cefixime, ceftriaxone, azithromycin, penicillin and ciprofloxacin for five N. gonorrhoeae strains, using their standard laboratory protocols. Minimal inhibitory concentrations (MICs) were compared to World Health Organisation (WHO) consensus results (or, if not available, reference laboratory results), while deviation by one doubling dilution was accepted. Data on laboratory procedures were collected via a standardised questionnaire. Generalized linear models and conditional inference trees (CTREE) were used to assess relationships between laboratory procedures and testing outcomes. Results: Twenty-one primary laboratories participated in the EQA in June 2018. 96% of ciprofloxacin MICs were reported within accepted deviations, as well as 88% for cefixime, 85% for ceftriaxone, 79% for penicillin and 70% for azithromycin. The use of interpretation standards and general laboratory procedures like agar base, incubation settings or the use of control strains strongly differed between laboratories. In statistical analysis, incubation time of cultures < 24 h was associated with correct measurements. Additionally, a 5% CO2 concentration was associated with correct results regarding azithromycin compared to 3%. CTREE analysis showed that incubation time, humidity and CO2 concentration had the greatest influence on the average deviation from consensus results. Conclusions: In conclusion, we report the development of a protocol for N. gonorrhoeae antimicrobial susceptibility testing in Germany. While testing results were in accordance with the expected consensus results in 70-96%, depending on the antibiotic agent, laboratory methodology was heterogeneous and may significantly affect the testing quality. We therefore recommend the development of a standard operating procedure (SOP) for N. gonorrhoeae susceptibility testing in Germany.

Cite

CITATION STYLE

APA

Selb, R., Jansen, K., Eckardt, M., Tamminga, T., Dudareva, S., Gassowski, M., … Buder, S. (2020). External quality assessment (EQA) of Neisseria gonorrhoeae antimicrobial susceptibility testing in primary laboratories in Germany. BMC Infectious Diseases, 20(1). https://doi.org/10.1186/s12879-020-05234-w

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free