Detecting sepsis patients who are at a high-risk of mechanical ventilation is important in emergency departments (ED). The respiratory rate oxygenation (ROX) index is the ratio of tissue oxygen saturation/fraction of inspired oxygen to the respiratory rate. This study aimed to investigate whether the ROX index could predict mechanical ventilator use in sepsis patients in an ED. This retro-spective observational study included quick sequential organ failure assessment (qSOFA) ≥ 2 sepsis patients that presented to the ED between September 2019 and April 2020. The ROX and ROX-heart rate (HR) indices were significantly lower in patients with mechanical ventilator use within 24 h than in those without the use of a mechanical ventilator (4.0 [3.2–5.4] vs. 10.0 [5.9–15.2], p < 0.001 and 3.9 [2.7–5.8] vs. 10.1 [5.4–16.3], p < 0.001, respectively). The area under the receiver operating characteristic (ROC) curve of the ROX and ROX-HR indices were 0.854 and 0.816 (both p < 0.001). The ROX and ROX-HR indices were independently associated with mechanical ventilator use within 24 h (adjusted hazard ratio = 0.78, 95% CI: 0.68–0.90, p < 0.001 and adjusted hazard ratio = 0.87, 95% CI 0.79–0.96, p = 0.004, respectively). The 28-day mortality was higher in the low ROX and low ROX-HR groups. The ROX and ROX-HR indices were associated with mechanical ventilator use within 24 h in qSOFA ≥ 2 patients in the ED.
CITATION STYLE
Ahn, S., Park, J., Song, J., Kim, J., Cho, H., & Moon, S. (2022). Association of ROX Index with Mechanical Ventilator Use in Sepsis Patients in the Emergency Department. Journal of Clinical Medicine, 11(2). https://doi.org/10.3390/jcm11020342
Mendeley helps you to discover research relevant for your work.