Abstract

RESULTS: Of the total number of patients (53) treated with this method of fixation, 31 of them were females and 22 males, mean age 52.7 years (28-75 years). The average time of surgery was 36.4 minutes (19-70 minutes). During the postoperative follow-up of all patients (53) operated by this method, six patients were lost in the further postoperative monitoring, so that 47 patients remained for final evaluation. The total incidence of nonunion of femoral neck fracture after surgery this method was 6.4% (three patients). Shortening of the femoral neck after fixation by this method was recorded in 27 cases, and what amounted to an average of 2.8 mm (1, 2 mm in nondislocated to 4.55 with dislocated fracture) and did not affect the functional outcome. During radiographic follow-up was not detected fracture implants. CONCLUSION: Self-tapping screws cannulated antirotation (SAF method) represent a reliable method of fixation of dislocated and nondislocated femoral neck fracture. The main prerequisite for the proper healing of femoral neck fractures with this method is that anatomical fracture reduction is achieved by a closed or open method. This way of fixation allows the early full weight bearing patient operated limb and faster postoperative functional recovery of the fracture healing in optimal time. INTRODUCTION: Femoral neck fractures are one of the most common fractures primarily the elderly, coupled with a high degree of morbidity and mortality. The treatment is applied a number of methods of internal fixation (multiple cannulated screws available, DHS system, cefalomedullary). At the Department of Orthopedics and Traumatology of Nis developed a new method of fixation of femoral neck fracture, which allows stable fixation of dislocated and nondislocated femoral neck fracture. Self-tapping antirotation fixation (SAF) using two cannulated screws to initial compression fractures intraoperative and postoperative dynamic linear compression of the fracture with early full support to the patient. MATERIAL AND METHODS: In the period between 2008 to 2012, 53 patients treated for femoral neck fracture in the Clinic for orthopedic and traumatology, Clinical center in Nis, Serbia, by SAF (the self-tapping cannulated screws antirotation; ORTOKON doo Nis). All patients were followed up after surgery in a minimum period of 13 weeks (13-106 weeks). The outcome was evaluated on the basis of clinical and radiological signs of fracture healing and the Harris hip score of functional recovery of the patient.

Cite

CITATION STYLE

APA

Kostić, I. M., Mitković, M. M., & Mitković, M. B. (2013). Results of the application of a new method of internal fixation of femoral neck fractures--self-tapping antirotation cannulated screws (SAF). Acta Chirurgica Iugoslavica, 60(2), 71–79. https://doi.org/10.2298/ACI1302071K

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free