Morphometric imaging biomarker identifies Alzheimer’s disease even among mixed dementia patients

2Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A definitive diagnosis of Alzheimer’s disease (AD), even in the presence of co-morbid neuropathology (occurring in > 50% of AD cases), is a significant unmet medical need that has obstructed the discovery of effective AD therapeutics. An AD-biomarker, the Morphometric Imaging (MI) assay on cultured skin fibroblasts, was used in a double-blind, allcomers (ages 55–90) trial of 3 patient cohorts: AD dementia patients, N = 25, all autopsy confirmed, non-AD dementia patients, N = 21—all autopsy or genetically confirmed; and non-demented control (AHC) patients N = 27. Fibroblasts cells isolated from 3-mm skin punch biopsies were cultured on a 3-D Matrigel matrix with movement dynamics quantified by image analysis. From counts of all aggregates (N) in a pre-defined field image and measures of the average area (A) of aggregates per image, the number-to-area ratios in a natural logarithmic form Ln(A/N) were determined for all patient samples. AD cell lines formed fewer large aggregates (cells clustered together) than non-AD or AHC cell lines. The cut-off value of Ln(A/N) = 6.98 was determined from the biomarker values of non-demented apparently healthy control (AHC) cases. Unequivocal validation by autopsy, genetics, and/or dementia criteria was possible for all 73 patient samples. The samples were collected from multiple centers—four US centers and one center in Japan. The study found no effect of center-to-center variation in fibroblast isolation, cell growth, or cell aggregation values (Ln(A/N)). The autopsy-confirmed MI Biomarker distinguished AD from non-AD dementia (non-ADD) patients and correctly diagnosed AD even in the presence of other co-morbid pathologies at autopsy (True Positive = 25, False Negative = 0, False Positive = 0, True Negative = 21, and Accuracy = 100%. Sensitivity and specificity were calculated as 100% (95% CI = 84 to 100.00%). From these findings, the MI assay appears to detect AD with great accuracy—even with abundant co-morbidity.

Cite

CITATION STYLE

APA

Chirila, F. V., Xu, G., Fontaine, D., Kern, G., Khan, T. K., Brandt, J., … Alkon, D. L. (2022). Morphometric imaging biomarker identifies Alzheimer’s disease even among mixed dementia patients. Scientific Reports, 12(1). https://doi.org/10.1038/s41598-022-21796-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free