Geometric and Dosimetric Evaluation of Deep Learning-Based Automatic Delineation on CBCT-Synthesized CT and Planning CT for Breast Cancer Adaptive Radiotherapy: A Multi-Institutional Study

15Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: We developed a deep learning model to achieve automatic multitarget delineation on planning CT (pCT) and synthetic CT (sCT) images generated from cone-beam CT (CBCT) images. The geometric and dosimetric impact of the model was evaluated for breast cancer adaptive radiation therapy. Methods: We retrospectively analyzed 1,127 patients treated with radiotherapy after breast-conserving surgery from two medical institutions. The CBCT images for patient setup acquired utilizing breath-hold guided by optical surface monitoring system were used to generate sCT with a generative adversarial network. Organs at risk (OARs), clinical target volume (CTV), and tumor bed (TB) were delineated automatically with a 3D U-Net model on pCT and sCT images. The geometric accuracy of the model was evaluated with metrics, including Dice similarity coefficient (DSC) and 95% Hausdorff distance (HD95). Dosimetric evaluation was performed by quick dose recalculation on sCT images relying on gamma analysis and dose-volume histogram (DVH) parameters. The relationship between ΔD95, ΔV95 and DSC-CTV was assessed to quantify the clinical impact of the geometric changes of CTV. Results: The ranges of DSC and HD95 were 0.73–0.97 and 2.22–9.36 mm for pCT, 0.63–0.95 and 2.30–19.57 mm for sCT from institution A, 0.70–0.97 and 2.10–11.43 mm for pCT from institution B, respectively. The quality of sCT was excellent with an average mean absolute error (MAE) of 71.58 ± 8.78 HU. The mean gamma pass rate (3%/3 mm criterion) was 91.46 ± 4.63%. DSC-CTV down to 0.65 accounted for a variation of more than 6% of V95 and 3 Gy of D95. DSC-CTV up to 0.80 accounted for a variation of less than 4% of V95 and 2 Gy of D95. The mean ΔD90/ΔD95 of CTV and TB were less than 2Gy/4Gy, 4Gy/5Gy for all the patients. The cardiac dose difference in left breast cancer cases was larger than that in right breast cancer cases. Conclusions: The accurate multitarget delineation is achievable on pCT and sCT via deep learning. The results show that dose distribution needs to be considered to evaluate the clinical impact of geometric variations during breast cancer radiotherapy.

References Powered by Scopus

U-net: Convolutional networks for biomedical image segmentation

65053Citations
N/AReaders
Get full text

Online Adaptive Radiation Therapy

177Citations
N/AReaders
Get full text

Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients

170Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Deep learning methods for enhancing cone-beam CT image quality toward adaptive radiation therapy: A systematic review

44Citations
N/AReaders
Get full text

A Review of the Metrics Used to Assess Auto-Contouring Systems in Radiotherapy

34Citations
N/AReaders
Get full text

Artificial Intelligence for Image Registration in Radiation Oncology

11Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Dai, Z., Zhang, Y., Zhu, L., Tan, J., Yang, G., Zhang, B., … Wang, X. (2021). Geometric and Dosimetric Evaluation of Deep Learning-Based Automatic Delineation on CBCT-Synthesized CT and Planning CT for Breast Cancer Adaptive Radiotherapy: A Multi-Institutional Study. Frontiers in Oncology, 11. https://doi.org/10.3389/fonc.2021.725507

Readers over time

‘22‘23‘24‘2505101520

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

88%

Researcher 1

13%

Readers' Discipline

Tooltip

Medicine and Dentistry 5

42%

Computer Science 4

33%

Engineering 2

17%

Materials Science 1

8%

Save time finding and organizing research with Mendeley

Sign up for free
0