An accuracy certified augmented reality system for therapy guidance

19Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Our purpose is to provide an augmented reality system for Radio-Frequency guidance that could superimpose a 3D model of the liver, its vessels and tumors (reconstructed from CT images) on external video images of the patient. In this paper, we point out that clinical usability not only need the best affordable registration accuracy, but also a certification that the required accuracy is met, since clinical conditions change from one intervention to the other. Beginning by addressing accuracy performances, we show that a 3D/2D registration based on radio-opaque fiducials is more adapted to our application constraints than other methods. Then, we outline a lack in their statistical assumptions which leads us to the derivation of a new extended 3D/2D criterion. Careful validation experiments on real data show that an accuracy of 2 mm can be achieved in clinically relevant conditions, and that our new criterion is up to 9% more accurate, while keeping a computation time compatible with real-time at 20 to 40 Hz. After the fulfillment of our statistical hypotheses, we turn to safety issues. Propagating the data noise through both our criterion and the classical one, we obtain an explicit formulation of the registration error. As the real conditions do not always fit the theory, it is critical to validate our prediction with real data. Thus, we perform a rigorous incremental validation of each assumption using successively: synthetic data, real video images of a precisely known object, and finally real CT and video images of a soft phantom. Results point out that our error prediction is fully valid in our application range. Eventually, we provide an accurate Augmented Reality guidance system that allows the automatic detection of potentially inaccurate guidance. © Springer-Verlag 2004.

Cite

CITATION STYLE

APA

Nicolau, S., Pennec, X., Soler, L., & Ayache, N. (2004). An accuracy certified augmented reality system for therapy guidance. Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics), 3023, 79–91. https://doi.org/10.1007/978-3-540-24672-5_7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free