Abstract

Bragg peak FLASH radiotherapy (RT) uses a distal tracking method to eliminate exit doses and can achieve superior OAR sparing. This study explores the application of this novel method in stereotactic body radiotherapy prostate FLASH-RT. An in-house platform was developed to enable intensity-modulated proton therapy (IMPT) planning using a single-energy Bragg peak distal tracking method. The patients involved in the study were previously treated with proton stereotactic body radiotherapy (SBRT) using the pencil beam scanning (PBS) technique to 40 Gy in five fractions. FLASH plans were optimized using a four-beam arrangement to generate a dose distribution similar to the conventional opposing beams. All of the beams had a small angle of two degrees from the lateral direction to increase the dosimetry quality. Dose metrics were compared between the conventional PBS and the Bragg peak FLASH plans. The dose rate histogram (DRVH) and FLASH metrics of 40 Gy/s coverage (V40Gy/s) were investigated for the Bragg peak plans. There was no significant difference between the clinical and Bragg peak plans in rectum, bladder, femur heads, large bowel, and penile bulb dose metrics, except for Dmax. For the CTV, the FLASH plans resulted in a higher Dmax than the clinical plans (116.9% vs. 103.3%). For the rectum, the V40Gy/s reached 94% and 93% for 1 Gy dose thresholds in composite and single-field evaluations, respectively. Additionally, the FLASH ratio reached close to 100% after the application of the 5 Gy threshold in composite dose rate assessment. In conclusion, the Bragg peak distal tracking method can yield comparable plan quality in most OARs while preserving sufficient FLASH dose rate coverage, demonstrating that the ultra-high dose technique can be applied in prostate FLASH SBRT.

References Powered by Scopus

Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries

75866Citations
N/AReaders
Get full text

Cancer statistics, 2023

10717Citations
N/AReaders
Get full text

Prostate cancer, version 2.2019

1035Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Spread-out Bragg peak FLASH: quantifying normal tissue toxicity in a murine model

4Citations
N/AReaders
Get full text

The Potential and Challenges of Proton FLASH in Head and Neck Cancer Reirradiation

3Citations
N/AReaders
Get full text

Fast spot order optimization to increase dose rates in scanned particle therapy FLASH treatments

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kaulfers, T., Lattery, G., Cheng, C., Zhao, X., Selvaraj, B., Wu, H., … Chang, J. (2024). Pencil Beam Scanning Proton Bragg Peak Conformal FLASH in Prostate Cancer Stereotactic Body Radiotherapy. Cancers, 16(4). https://doi.org/10.3390/cancers16040798

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

100%

Readers' Discipline

Tooltip

Medicine and Dentistry 2

50%

Agricultural and Biological Sciences 1

25%

Engineering 1

25%

Article Metrics

Tooltip
Mentions
Blog Mentions: 1
News Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free